Adtran L128 Manual Do Utilizador

Página de 200
Appendix B: Log Messages
61202.070L1-1
Express L128/L128T User Manual
133
NOT end2end ISDN
level 4
The path that the call was routed over is not ISDN from end-to-end.  This is a 
warning and is most often seen for POTS calls.
Power Up - last down cause: <reason>
level 0 (displayed as level 1 after the unit is reset)
This is the <reason> for the last reset.  Most are caused by internal errors.  Pos-
sible reasons are:
Bus Error
 - Bad address occurred on the internal bus
Kernel error
 - General operating system error
No SBCs
 - Mail resources used up or lost
Router stack error
 - Fatal error in protocol stack
general panic
 - general error
no rip
 - rip tasks could not start
out of memory
 - out of available memory
out of TCP ports
 - all TCP ports are used up
unknown error
 - unknown fatal error has occurred
Set timer error
 - Cannot set real time clock
Software Watch Dog Reset
 - Software watchdog was not updated
Probe: all ports busy
level 3
All ports were busy when it was time to probe.  An attempt will be made on 
the next probe interval.
Probe failed
level 2
An attempt to connect to a probe site failed.
Probing <name>
level 4
The Express L128/L128T is making an outgoing call to the destination speci-
fied by the description in the Connection List in order to get an update on 
routes.
POTS call bump
level 4
The Express L128/L128T has dropped bandwidth on an existing data call so 
that a POTS call can be connected.