2.9.6 Connecting to a 100-pin 0.5mm pitch Foot Pattern (Part 2) 
Here following is a procedure of connecting to a 100-pin 0.5mm pitch foot pattern on the user system using the M3T-100LCC-
QSD (not included). For details on the M3T-100LCC-QSD (not included), refer to its user's manual. 
 
(1)  Attach the TQPACK100SD to the user system. 
(2)  Attach the TQSOCKET100SDG included with the M3T-100LCC-QSD to the TQPACK100SD. 
(3)  Attach the M3T-100LCC-QSD to the TQSOCKET100SDG. 
(4)  Attach the CN2 side of the M30800T-PTC to the J4 side of the M306NKT-EPB. 
(5)  Attach the M30800T-PTC to the M3T-100LCC-QSD. 
 
 
M3T-100LCC-QSD
(not included)
CN2 side
(4)
(5)
M30800T-PTC
(3)
(2)
TQSOCKET100SDG
TQPACK100SD
(1)
100-pin 0.5mm pitch
No. 1 pin
User system
M3T-FLX160-EPB
M306NKT-EPB
(PLQP100KB-A) foot pattern
 
 
 
Figure 2.14 Connecting to a 100-pin 0.5mm pitch foot pattern (Part 2) 
 
  CAUTION 
Note on Connecting the User System: 
 
z
 Take care not to attach a converter board in a wrong direction. It may cause a fatal damage to the emulator and 
user system. 
 
IMPORTANT 
Note on Connectors of the Converter board: 
 
z
 The connectors of the M30800T-PTC and M3T-100LCC-QSD are guaranteed for only 50 insertion/removal 
iterations.