RAD Data comm IPmux-11 Manual Do Utilizador

Página de 148
Installation and Operation Manual 
Chapter 4  Configuration 
IPmux-11 Ver. 2.00 
Configuring IPmux-11 for Operation 
4-25 
2.  From the Bridge menu, select Aging time and define a period of time in 
seconds from the moment when a node is disconnected from the network 
segment or becomes inactive and removal of the node address from the 
database.  
3. Select Erase MAC table, if you intend to delete all learned addresses from the 
MAC table.  
4. Select Bridge policy, and from the Bridge Policy menu (
) define the 
following: 
 
VLAN tagging (operation mode for the corresponding port of internal 
switch):  
 
Transparent 
 
Tag (Tagged) 
 
Untag (Untagged) 
 
DoubleTag (Double Tagged) 
 
Default VLAN ID (VLAN associated with untagged frames arriving at the 
port): 1–4095 
 
Default VLAN Priority: 0–7 
 
Rate limit:  
 
User port: Disable, 256 kbps, 512 kbps, 1 Mbps, 2 Mbps, 4 Mbps, 
8 Mbps, 16 Mbps, 32 Mbps, 64 Mbps 
 
Network port: Disable, 256 kbps, 512 kbps, 1 Mbps, 2 Mbps, 4 Mbps, 5 
Mbps, 8 Mbps, 10 Mbps, 16 Mbps, 20 Mbps, 25 Mbps, 40 Mbps, 50 
Mbps, 80 Mbps 
 
Selected rate limiting value for the user port changes available default VLAN priority 
options for this port in the following manner: 
Rate Limiting 
Default VLAN Priority 
0–8 Mbps  
0–7 
16 Mbps   
0–7 
32 Mbps   
2–7 
64 Mbps*  
4–7 
* – Since the user traffic entering the switch via ports with 64 Mbps rate limiting 
receives high priority, it may interfere with TDM traffic, which has high priority 
by default. 
 
 
5. Select VLAN table, and from the VLAN Table menu (
) configure the 
following:  
 
Channel:  
 
Network-Eth1 
 
User1-Eth2 
 
User2-Eth3 
 
VLAN ID (Specifies VLAN, which the current bridge port will be a member 
of): 1–4095 
Note