4.  If you are not installing your board in an ISA form 
factor PCI slot, remove the ISA edge retainer from the 
board. 
5.  Using the slot’s board guides, insert the edge connector 
of the board into the bus slot. Press firmly until the 
board is securely seated in the slot. 
6.  Replace and tighten the retaining screw to secure the 
board firmly in the chassis slot (if applicable). 
 
7.  Connect external digital telephone cable to the RJ-48C 
jack on the board bracket. 
8.  Select a new PCI slot and repeat steps 3-7 for each 
board you are installing. 
9.  Use the CT Bus cable to connect the board(s) you are 
installing to other boards in the system. 
NOTE:  Your system may include both CT Bus and SCbus 
boards. To connect both board types, you must install a CT 
Bus/SCbus Adapter on one of the CT Bus boards in a 
system. See the CT Bus/SCbus Adapter Quick Install Card 
for installation details about the Adapter and the bus 
cables. Contact your sales representative to order an 
Adapter. 
10. Install CT Bus Termination Jumpers only on boards 
located at each end of the CT Bus cable. See Physical 
Description
 
11. Replace the computer cover when finished and reconnect 
the power cords. 
12. Turn the power to the chassis ON
  CAUTION:  If your BIOS is set to use Plug and Play 
technology and there are ISA boards in your system, an 
IRQ conflict can be created if a DM3 board is assigned 
the same IRQ as an ISA board. This could cause the 
machine to stop responding. You can prevent this by 
entering the BIOS and reserving the appropriate IRQs 
(those used by your ISA boards) for ISA use only. 
 
After Installing the
 
Hardware 
After installing the hardware, proceed with the system 
software installation as described in the Dialogic
®
 System 
Software documentation (if applicable). 
For technical specifications and product information go to: 
http://www.dialogic.com/products.htm. 
Warranty and Return 
Information
 
Warranty Period 
For specific warranty information for this board, refer to the 
Warranty section of the Products page, located at this URL: 
http://www.dialogic.com/warranties/.  
 
Contacting Technical Support 
 
Dialogic provides technical support for its products through a 
network of value added distributors who are trained to answer 
technical questions on installing and configuring Dialogic
®
 
products.  If you are unsure how to contact your support 
channel, please call Dialogic in the United States at 973-967-
6600 (9am-5pm EST) and we will assist in obtaining the 
appropriate support channel.  Outside the United States please 
refer to http://www.dialogic.com/support/contact to obtain 
local contact information. 
 
Dialogic also provides direct support via Dialogic
®
 Pro™ 
Services agreements.  For more details of direct support from 
Dialogic please refer to: 
 
Returning a Product 
To return a board for warranty repair or any other returns, 
please refer to the following: 
http://www.dialogic.com/support/hwfaults.  
To return a board for warranty repair, please refer to the 
following: http://www.dialogic.com/support/hwfaults.  For all 
other returns, contact your vendor or Dialogic Customer 
Support (for more information, see 
http://www.dialogic.com/support/contact/ ). 
 
Sales Assistance
 
Dialogic, Diva, Eicon, Eicon Networks, Eiconcard , Dialogic Pro and SIPcontrol, among others, are either 
registered trademarks or trademarks of Dialogic. Dialogic's trademarks may be used publicly only with 
permission from Dialogic. Such permission may only be granted by Dialogic’s legal department at 9800 
Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada H4M 2V9. Any authorized use of Dialogic's trademarks 
will be subject to full respect of the trademark guidelines published by Dialogic from time to time and any use of 
Dialogic’s trademarks requires proper acknowledgement.  The names of actual companies and products 
mentioned herein are the trademarks of their respective owners. 
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH DIALOGIC
®
 
PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY 
INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED 
IN A SIGNED AGREEMENT BETWEEN YOU AND DIALOGIC, DIALOGIC ASSUMES NO LIABILITY 
WHATSOEVER, AND DIALOGIC DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING 
TO SALE AND/OR USE OF DIALOGIC PRODUCTS INCLUDING LIABILITY OR WARRANTIES 
RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT 
OF ANY INTELLECTUAL PROPERTY RIGHT OF A THIRD PARTY. 
It is possible that the use or implementation of any one of the concepts, applications, or ideas described in this 
document, in marketing collateral produced by or on web pages maintained by Dialogic may infringe one or 
more patents or other intellectual property rights owned by third parties. Dialogic does not provide any 
intellectual property licenses with the sale of Dialogic products other than a license to use such product in 
accordance with intellectual property owned or validly licensed by Dialogic and no such licenses are provided 
except pursuant to a signed agreement with Dialogic. More detailed information about such intellectual property 
is available from Dialogic’s legal department at 9800 Cavendish Blvd., 5
th
 Floor, Montreal, Quebec, Canada 
H4M 2V9. Dialogic encourages all users of its products to procure all necessary intellectual property 
licenses required to implement any concepts or applications and does not condone or encourage any 
intellectual property infringement and disclaims any responsibility related thereto. These intellectual 
property licenses may differ from country to country and it is the responsibility of those who develop the 
concepts or applications to be aware of and comply with different national license requirements.
  
 
If you have a sales question, please contact your 
local Sales Representative or the Regional Sales Office 
for your area. Address, telephone and fax numbers, are 
available at the Dialogic website located at: 
http://www.dialogic.com/contact.htm
 
To purchase Dialogic
®
 products, please refer to the following 
website to locate the appropriate supplier.  
http://www.dialogic.com/purchase.htm
All contents of this document are furnished for informational use only and are subject to change without notice 
and do not represent a commitment on the part of Dialogic Corporation or its subsidiaries (“Dialogic”). 
Reasonable effort is made to ensure the accuracy of the information contained in the document. However, 
Dialogic does not warrant the accuracy of this information and cannot accept responsibility for errors, 
inaccuracies or omissions that may be contained in this document.  
Dialogic products are not intended for use in medical, life saving, life sustaining, critical control or safety 
systems, or in nuclear facility applications. 
Note:
of connectors (drops). 
Your CT Bus cable may 
have a different number 
CT Bus
Cable
 
Installing the CT Bus Cable
Colored
Stripe
(Pin 1)
 
Installing a PCI Board
ISA Slot
PCI Slot
PCI
Board
Computer
Chassis
Remove
Cover
Plate
Network Interface
Cable Connector
CHASSIS GROUND
CHASSIS GROUND
CHASSIS GROUND
XMIT_TIP
XMIT_RING
CHASSIS GROUND
RCV_TIP
RCV_RING
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
Pinouts for t he RJ048C
Jack on Bracket
 
Connecting to the RJ-48C Jack
Pin 1