6.6 Others 
6.6.1  Speed Limit 
The max. servo motor speed can be limited by using parameter P1-55 no matter in position, speed or 
torque control mode. 
The command source of speed limit command is the same as speed command. It can be the external 
analog voltage but also can be internal parameters (P1-09 to P1-11). For more information of speed 
command source, please refer to chapter 6.3.1. 
The speed limit only can be used in torque mode (T mode) to limit the servo motor speed. When the 
torque command is the external analog voltage, there should be surplus DI signal that can be treated as 
SPD0~1 and be used to select speed limit command (internal parameter). If there is not enough DI 
signal, the external voltage input can be used as speed limit command. When the Disable / Enable 
Speed Limit Function Settings in parameter P1-02 is set to 1, the speed limit function is activated.  
The timing chart of speed limit is shown as the figure below: 
Disable / Enable Speed Limit Function
Settings in parameter P1-02 is set to 1
SPD0~1 INVALID
SPD0~1 VALID
Disable / Enable Speed Limit Function
Settings in parameter P1-02 is set to 0
 
Command Source Selection of Speed Limit 
 
6.6.2  Torque Limit 
The command source of torque limit command is the same as torque command. It can be the external 
analog voltage but also can be internal parameters (P1-12 to P1-14). For more information of torque 
command source, please refer to chapter 6.4.1. 
The torque limit only can be used in position mode (P mode) and speed mode (S mode) to limit the 
output torque of servo motor. When the position command is the external pulse and speed command is 
the external analog voltage, there should be surplus DI signal that can be treated as TCM0~1 used to 
select torque limit command (internal parameter). If there is not enough DI signal, the external voltage 
input can be used as torque limit command. When the Disable / Enable Torque Limit Function Settings 
in parameter P1-02 is set to 1, the torque limit function is activated.  
The timing chart of torque limit is shown as the figure below: 
TCM0~1 INVALID
TCM0~1 VALID
Disable / Enable Torque Limit Function
Settings in parameter P1-02 is set to 1
Disable / Enable Torque Limit Function
Settings in parameter P1-02 is set to 0
 
Command Source Selection of Torque Limit