Delta Electronics ASDA-B Series Manual Do Utilizador

Página de 321
Chapter 7  Servo Parameters|ASDA-B Series
 
7-80  
 
Revision January, 2009
 
Table 7.B  Output Function Definition 
Setting value of P2-18 ~ P2-20: 01 
DO Name 
DO Function Description 
Control Mode
SRDY 
Servo ready. SRDY is activated when the servo drive is ready to run. All 
fault and alarm conditions, if present, have been cleared. 
P, S, T 
 
   
Setting value of P2-18 ~ P2-20: 02 
DO Name 
DO Function Description 
Control Mode
SON 
Servo On. SON is activated when control power is applied to the servo 
drive. The drive may or may not be ready to run as a fault / alarm 
condition may exist. Servo ON (SON) is "ON" with control power applied 
to the servo drive, there may be a fault condition or not. The servo is not 
ready to run. Servo ready (SRDY) is "ON" where the servo is ready to 
run, NO fault / alarm exists. (P2-51 should turn servo ready SRDY off / 
on) 
P, S, T 
 
Setting value of P2-18 ~ P2-20: 03 
DO Name 
DO Function Description 
Control Mode
ZSPD 
At Zero speed. ZSPD is activated when the drive senses the motor is 
equal to or below the Zero Speed Range setting as defined in parameter 
P1-38. For Example, at default ZSPD will be activated when the drive 
detects the motor rotating at speed at or below 10 rpm. ZSPD will 
remain activated until the motor speed increases above 10 RPM. 
P, S, T 
 
Setting value of P2-18 ~ P2-20: 04 
DO Name 
DO Function Description 
Control Mode
TSPD 
At Speed reached. TSPD is activated once the drive has detected the 
motor has reached the Target Rotation Speed setting as defined in 
parameter P1-39. TSPD will remain activated until the motor speed 
drops below the Target Rotation Speed. 
 
Setting value of P2-18 ~ P2-20: 05 
DO Name 
DO Function Description 
Control Mode
TPOS 
At Positioning completed. When the drive is in position mode, TPOS will 
be activated when the position error is equal and below the setting value 
of P1-54.