Chapter 8  MODBUS Communications|ASDA-B Series 
 
8-8  
 
Revision January 2009
 
8.3  MODBUS Communication Protocol 
When using RS-232/485 serial communication interface, each ASDA-B series AC servo drive has a pre-
assigned communication address specified by parameter “P3-00”. The computer then controls each AC 
servo drive according to its communication address. ASDA-B series AC servo drive can be set up to 
communicate on a MODBUS networks using on of the following modes: ASCII (American Standard Code for 
Information Interchange) or RTU (Remote Terminal Unit). Users can select the desired mode along with the 
serial port communication protocol in parameter “P3-02”. 
„
 
Code Description:  
ASCII Mode:  
Each 8-bit data is the combination of two ASCII characters. For example, a 1-byte data: 64 Hex, shown as 
‘64’ in ASCII, consists of ‘6’ (36Hex) and ‘4’ (34Hex). 
The following table shows the available hexadecimal characters and their corresponding ASCII codes. 
Character 
‘0’ 
‘1’ 
‘2’ 
‘3’ 
‘4’ 
‘5’ 
‘6’ 
‘7’ 
ASCII 
code 
30H 31H 32H 33H 34H 35H 36H 37H 
Character 
‘8’ 
‘9’ 
‘A’ 
‘B’ 
‘C’ 
‘D’ 
‘E’ 
‘F’ 
ASCII 
code 
38H 39H 41H 42H 43H 44H 45H 46H 
RTU Mode:  
Each 8-bit data is the combination of two 4-bit hexadecimal characters. For example, a 1-byte data: 64 Hex. 
„
 
Data Format:  
10-bit character frame (For 7-bit character) 
7N2 
Start
  bit
0
1
2
3
4
5
6
Stop
bit
7-data bits
10-bits character frame
Stop
bit
 
7E1 
Even
parity
Start
  bit
0
1
2
3
4
5
6
Stop
bit
7-data bits
10-bits character frame
 
7O1 
Odd
parity
Start
  bit
0
1
2
3
4
5
6
Stop
bit
7-data bits
10-bits character frame