10.3  Clearing Servo Drive Faults 
Display 
Fault Name 
Clearing Method 
ALE   
Overcurrent 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
ALE   
Overvoltage 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
ALE   
Undervoltage 
This fault message can be removed automatically 
after the voltage has returned within its 
specification.  
ALE   
Z Pulse shift 
Restart the servo drive.  
ALE   
Regeneration error 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
ALE   
Overload 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
ALE   
Overspeed 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
ALE   
Abnormal pulse control 
command 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
ALE   
Excessive deviation 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
ALE 10/ALE   
Serial communication error
Turn ARST (DI signal) ON to clear the fault. This 
fault message can also be removed automatically 
after the communication is normal. 
ALE 11/ALE   
Encoder error (Position 
detector fault) 
Restart the servo drive.  
ALE 12/ALE   
Adjustment error 
This fault message can be removed after the 
wiring of CN1 connector (I/O signal connector) is 
removed and auto adjustment function is 
executed. 
ALE 13/ALE   
Emergency stop activated 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
ALE 14/ALE   
Reverse limit switch error 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
ALE 15/ALE   
Forward limit switch error 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
ALE 16/ALE   
IGBT temperature error 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
ALE 17/ALE   
Memory error 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
ALE 18/ALE   
Serial communication time 
out 
Turn ARST (DI signal) ON to clear the fault. This 
fault message can also be removed automatically 
after the communication is normal. 
ALE 19/ALE   
Motor type error 
Restart the servo drive.  
ALE 20/ALE 
 
Input power phase loss 
This fault message can be removed automatically 
after input power phase lost problem is solved.