4.2.4  Fault Code Display Operation  
After entering the parameter mode P4-00 to P4-04 (Fault Record), press SET key to display the 
corresponding fault code history for the parameter or press UP arrow key to display the fault code of H1 
to H5 in order. H1 indicates the most recent occurred fault code, H2 is the previous occurred fault code 
before H1 and so on.  
Figure 4.15 
 
 
4.2.5  JOG Operation 
After entering parameter mode P4-05, the users can follow the following steps to perform JOG operation 
or press FUNC key on the digital keypad to enter into JOG mode (parameter setting mode of P4-05) 
directly. 
 
Step 1  Press the FUNC key to display the JOG rpm speed. (The default value is 20 rpm). 
Step 2  Press the UP or DOWN arrow keys to increase or decrease the desired JOG speed. (This also 
can be undertaken by using the SHIFT key to move the cursor to the desired unit column (the 
effected number will flash) then changed using the UP and DOWN arrow keys. The example 
display in Figure 4.16 is adjusted as 21rpm.) 
Step 3  Press the SET key when the desired JOG speed is set. The Servo Drive will display 
 and JOG LED will light up. 
Step 4  Press the UP or DOWN arrow keys to jog the motor either CCW or CW. The motor will only 
rotate while the arrow key is activated. 
Step 5  To change JOG speed again, press the MODE key. After JOG speed is changed, press the 
SET key and the JOG operation will run again. Refer back to #2 and #3 to change speed.