Cisco Systems 700 MHz Manual Do Utilizador

Página de 134
2-19
Installation and Upgrade Guide for Cisco Unified MeetingPlace Audio Server 6.x
OL-13417-01
Chapter 2      Installing the Cisco Unified MeetingPlace 8100 Series Hardware
About Telephony Configurations for E1 and T1 PRI Cisco Unified MeetingPlace Systems
Connecting E1 or T1 PRI Telephony Cables with One Multi Access Blade 
MP-MA-16-PRI
To Connect the E1 or T1 PRI Telephony Cables with One Multi Access Blade MP-MA-16-PRI
Step 1
Locate the following items shipped with the Cisco Unified MeetingPlace Audio Server:
  •
E1 or T1 PRI telephony cables.
  •
Breakout box, which should already be mounted above the Cisco Unified MeetingPlace Audio 
Server)
  •
Trunk card interface cable assemblies (50-pin Amphenol cables).
Step 2
Attach the far end of the first E1 or T1 PRI telephony cable to the equipment that will connect with Cisco 
Unified MeetingPlace. 
In many cases, the other equipment has an RJ-48c socket in which to plug the E1 or T1 PRI telephony 
cable. Alternately, the other equipment will be connected to a punchdown block. In this case, you will 
need to determine the block’s connection diagram and then connect to it with discrete wires from the 
cable.
Step 3
Plug the other end of the first E1 or T1 PRI telephony cable into the RJ-45 jack, labeled 1, on the far left 
of the front of the breakout box. Continue from left to right as needed. See 
.
Figure 2-13
Breakout Box (Front View)
Step 4
Repeat 
 until all the E1 or T1 PRI telephony cables are connected to the breakout box.
Step 5
Connect the first trunk card cable assembly (50-pin Amphenol cable) to the back of the breakout box by 
securing the screws on both ends.
Looking at the back of the breakout box, the connector on the right of the breakout box is for spans 
1 to 8, and the connector on the left of the breakout box is for spans 9 to 16. Place the first trunk card 
cable assembly into the connector on the right. See 
.
Figure 2-14
Breakout Box (Back View)
Step 6
Connect the other end of the first trunk card cable assembly (50-pin Amphenol cable) into the 
Multi Access Blade transition module by securing the screws on both ends
For the Cisco Unified MeetingPlace 8106, the connector on the right of the Multi Access Blade transition 
module is for spans 1 to 8 and the connector on the left of the Multi Access Blade transition module is 
for spans 9 to 16. Place the first trunk card cable assembly into the connector on the right. See