Analog-to-Digital Converter (ADC)
MCF52211 ColdFire® Integrated Microcontroller Reference Manual, Rev. 2
26-30
Freescale Semiconductor
 
completion of the previous scan. In loop parallel scan modes, both converters restart together if 
SIMULT equals 1 and restart independently if SIMULT equals 0. All subsequent start and sync pulses are 
ignored after the scan begins. Scanning can only be terminated by setting a STOPn bit. Use STOP0 in the 
CTRL1 register if operating in a sequential or simultaneous parallel mode. If operating in a 
non-simultaneous parallel mode, use STOP0 to stop converter A and STOP1 in the CTRL2 register to stop 
converter B.
26.5.6
Scan Configuration and Control
The operation of the ADC module is controlled by the CTRL1 and CTRL2 registers. The CTRL1 register 
is described in 
depends on whether the ADC is in sequential-scan or parallel-scan mode (see 
” and 
”, respectively). 
These are used to set the scan mode, configure channels, and start/stop scans.
The ADC can operate in several sequential or parallel scan modes, as determined by CTRL1[SMODE]. 
These are summarized in 
. When the ADC operates in a parallel scan mode, its functionality 
can be further controlled by CTRL2[SIMULT].
All scan modes make use of the 8 sample slots defined by the ADLST1 and ADLST2 registers. A scan is 
the process of stepping through these sample slots, converting the analog input indicated by that slot, and 
storing the result. Slots that are not required may be disabled by writing 1 to the appropriate bits of the 
SDIS register. 
Input pairs AN0-1, AN2-3, AN4-5, and AN6-7 may be configured as differential pairs using 
CTRL1[CHNCFG]. When a slot in ADLSTn refers to either member of a differential pair, a differential 
measurement on that pair is made; otherwise, a single-ended measurement is taken on that input. The 
details of single-ended and differential measurements are described in 
”, respectively.
CTRL1[SMODE] determines whether the slots are used to perform a sequential scan of up to 8 samples 
or 2 parallel scans up to 4 samples. It also controls how these scans are initiated/terminated and whether 
the scans are performed one time or repetitively. For more details, please see 
.
Parallel scans may be simultaneous or non-simultaneous depending on CTRL2[SIMULT]. This bit only 
applies to parallel operating modes and is ignored during sequential operating modes. During simultaneous 
parallel scans, A and B converters scan synchronously using one set of shared controls (CTRL1 register). 
During non-simultaneous scans, the A and B converters operate asynchronously with each converter using 
its own independent set of controls (CTRL1 for A and CTRL2 for B). Refer to