Nortel Networks AN/DC Manual Do Utilizador

Página de 150
Installing and Operating AN/DC and ANH-8/DC Systems
D-6
312410-A Rev 00
Figure D-3.
Cable 7224 (X.21 Compliant)
Table D-8.
X.21 Interface (Order No. 7224)
Nortel Networks Termination
Remote Termination
Pin
Signal
Pin
Signal
  2
Send Data+
  2
Send Data+
16
Send Data-
  9
Send Data-
  4
Request to Send+
  3
Request to Send+
18
Request to Send-
10
Request to Send-
  3
Receive Data+
  4
Receive Data+
17
Receive Data-
11
Receive Data-
  9
Data Carrier Detect+
  5
Data Carrier Detect+
23
Data Carrier Detect-
12
Data Carrier Detect-
10
Send Timing+
  6
Send Timing
24
Send Timing-
13
Receive Timing
  7
Signal Ground
  8
Signal Ground
  1
Frame Ground
  1
Frame Ground
Local Wire Connections
Pin 41 > 43
Pin 28 > 30
Pin 14 > 15
Pin 1
Pin 16
Pin 31
Pin 15
Pin 30
Pin 44
44-position D-SUB plug with screw locks -
 ground shield connected to backshell
15 FEET
Pin 13
Pin 1
Pin 25 
Pin 14
25-position D-SUB plug with screw locks -
 ground shield connected to backshell
AN0078A