Nortel Networks AN/DC Manual Do Utilizador

Página de 150
Requirements for European Operation
312410-A Rev 00
D-9
 
The creepage distances apply to the normal office environment. When the local 
environment within the host chassis is subject to conductive pollution or dry 
nonconductive pollution that could become conductive due to condensation, the 
creepage distances shown in parentheses in 
 will apply.
The clearance and creepage distance between adjacent points should be checked 
as follows:
The clearance distance (X) is the shortest distance measured between two 
points through the air.
The creepage distance (Y) is the shortest distance between two points 
measured across a surface.
You should obtain advice from a competent telecommunications safety engineer if 
in doubt. Failure to install the ISDN BRI according to these instructions will 
invalidate the General Approval.
ISDN BRI Upgrade Module Safety Status
 lists the safety status of interconnection points to the connection of 
other equipment.
Table D-10.
ISDN BRI Clearances and Creepage Distances
Clearance (X)
Creepage (Y)
Voltage used or generated by other parts 
of the host or expansion card
2.0 mm
2.4 (3.8) mm
Up to 50 V rms or V dc
2.6 mm
3.0 (4.8) mm
Up to 125 V rms or V dc
4.0 mm
5.0 (8.0) mm
Up to 250 V rms or V dc
4.0 mm
6.4 (10.0) mm
Up to 300 V rms or V dc
Table D-11.
ISDN BRI Safety Status (Order Nos. 24000, 24000-S, 50022, 
AE0004006, AE0011013, and AE0011019)
Port Location
Port Description
Type of Circuit
ISDN
BRI ISDN
TNV at SELV levels
P6
Host Port
SELV