Installing the AN/DC
312410-A Rev 00
1-7
To install the AN/DC in a rack:
1.
Attach each flange bracket to the AN/DC
as follows:
a.
Align the flange holes with the AN/DC mounting holes.
b.
Insert a flange screw through each flange hole and into the AN/DC.
c.
Tighten each flange screw with a Phillips screwdriver.
Figure 1-3.
Attaching Flange Brackets to the AN/DC
2.
Place the AN/DC in the rack, aligning the flange holes with the holes in
the front vertical supports of the rack
the front vertical supports of the rack
.
3.
Insert a cagenut screw through each flange hole and into the
corresponding holes in the front vertical supports of the rack.
corresponding holes in the front vertical supports of the rack.
4.
Tighten each cagenut screw with a Phillips screwdriver.
Note:
If the rack’s rail does not have threaded holes, use the cagenuts along
with the cagenut screws. Otherwise, just use the cagenut screws.
Screws