Nortel Networks NN44200-700 Manual Do Utilizador

Página de 150
40
Chapter 3 Hardware troubleshooting
Trouble
Action
All DSP diagnostics fail at
system startup.
Ensure that the MPB16-4 boards are release 5 or later.
Ensure that the PCI backplane does not have Intel PCI bridge chips.
Shut down the server and open the lid. Power up the server and
check if the PCI LED on the MPB16-4 board is still on after startup.
If the LED still stays on, shut down the server and replace the board.
If the PCI LED comes on at system startup and then turns off, but
the other four green LEDs are still off after the system booted to the
operating system, check the HAL and ensure that all its components
are working properly. If the HAL components are working properly,
one or more MPC8 cards can be defective. Replace the defective
MPC8 cards.
If your system has two MPB16-4 boards and both have the same
symptoms, ensure that the correct driver is installed.
If only one MPB16-4 board seems to be defective, swap the boards.
If the presumed defective board works after the swapping, then the
PCI backplane is defective and you must replace it. If the presumed
defective board does not work, then you must replace it.
All the DSPs and DS30
links are reported as "All
busy", but the monitor
shows that the resources
are only partially busy
(Option 11 Meridian 1
configurations only).
The switch and the CallPilot system do not have the same ground
connection. Ensure that both systems are plugged into the same
power outlet and connected to a single-point ground reference.
The system starts up but
attempts to boot to the
operating system from the
network.
The RAID packs are either not configured or degraded. The RAID
system is not operational. Proceed as follows:
Power down the system, plug the RAID card into the next set of
four PCI slots and then turn on the system. If the system boots
correctly to the operating system, then the PCI backplane is
defective and you must replace it.
Power down the system, open the server lid and turn on the
system. If more than four lights remain on, the RAID controller is
faulty. Power down the system, reseat the controller card, and
turn on the system. If this action does not remedy the trouble,
then the RAID controller card is defective and you must replace
it.
Nortel CallPilot
Troubleshooting Reference Guide
NN44200-700
01.05
Standard
5.0
26 June 2007
Copyright © 2007, Nortel Networks
.