Fujitsu F2 MC-16 Manual Do Utilizador

Página de 354
124
CHAPTER 2  DEPENDENCE FUNCTIONS
Setting Events
Set events using the SET EVENT command.
The starting/ending point of time measurement and points to measure pass count are specified by events.
Events at 8 points (1 to 8) can be set. However, in the performance measurement, the intervals, starting event
number and ending event number are fixed in the following combination.
- Measuring Time
Four intervals have the following fixed event number combination.
- Measuring Count
The specified events become performance measurement points automatically.
Executing Program
Start measuring when executing a program by using the GO or CALL command. If a break occurs during
interval time measurement, the data for this specific interval is discarded.
Displaying Performance Measurement Data
Display performance measurement data by using the SHOW PERFORMANCE command.
Clearing Performance Measurement Data
Clear performance measurement data by using the CLEAR PERFORMANCE command.
[Example]
>CLEAR PERFORMANCE
>
Interval
Starting Event Number
Ending Event Number
1 1 
2 3 
3 5 
4 7