ENVIRONNEMENTAL CLASSES
TYPE OF TEST
STANDARDS
STORAGE
TRANSPORTATION
OPERATING (PORT USE)
Class 1.2
Class 2.3
Class 7.3
Cold
IEC 68-2.1
-25° C                              72 h
-40° C                               72 h
-20° C (GSM900)                 16 h
Ab test
-10° C (GSM1800/1900)    16h
Dry heat
IEC 68-2.2
+70° C                              72 h
+70° C                               72 h
+55° C                               16 h
Bb test
Change of temperature
IEC 68-2.14
-40° / +30° C              5 cycles
-20° / +30° C (GSM900) 3 cycles
Na/Nb test
                                     t1 = 3 h
-10° / +30° C (GSM1800/1900):
3 cycles                    t1 = 3 h
Damp heat
IEC 68-2.30
 +30° C               2 cycles
 +40° C               2 cycles
 +40° C               2 cycles
cyclic
Db test
90% - 100% RH                                    
90% - 100% RH                                    
90% - 100% RH
variant 1
variant 1
variant 1
Damp heat
IEC 68-2.56
 +30° C               4 days
 +40° C               4 days
 +40° C               4 days
Cb test
Sinusoidal vibration
IEC 68-2.6
5 - 62 Hz     :               5 mm / s
Fc test
62 - 200Hz :               2 m / s2
3 x 5 sweep cycles
5 - 20 Hz     :        0.96 m2 / s3
10 -12 Hz     :        0.96 m2 / s3
Random vibration
IEC 68-3.36
20 - 500Hz :         - 3 dB / oct
12 - 150Hz :         - 3 dB / oct
wide band
Fdb test
3 x 10 min
3 x 30 min
 
Figure 45. Environmental classes