Lynx Series 5000 Rack Frame Manual Do Utilizador

Página de 39
Reference Manual R FR 5010 Version1.4
 
Page 14   
 
Power Supply 
The R FR 5010 / R FR 5011 includes the primary 
power supply. A second identical power supply 
can be added for redundancy. The Power supply is 
a sophisticated design designed for critical 
applications and includes power filtering and 
integral microprocessor. This monitors the supply 
operation and reports into the control system. 
Should a fault develop, the errors are alarmed in 
the following ways: 
 
•  Via the LED located on the front of the supply 
(Figure 4). 
 
•  Via a GPO alarm via the alarm connector on 
the termination panel (figure 5), if a controller 
option is fitted 
 
•  Via the control system (if installed) 
 
If the redundant power supply is installed, the 
system will switch supplies automatically in the 
event of primary supply failure, with no interruption 
to the normal operation of the rack. 
 
The supply has a noiseless integral DC fan for 
cooling.  
 
The supply is installed and removed from the front 
of the rack. Removing the rack front cover plate 
provides access. The supply is secured firmly in 
place with a screw located at the bottom front of 
the unit (figure 4).