Carrier ASPBA1CCA016 Manual Do Utilizador

Página de 4
Home Standby - 16kW
TRANSFER SWITCH & EMERGENCY LOAD CENTER
Models: ASPBS1CC016 & ASPBA1CC016
No. of Poles ......................................................................................................................................... 2
Current Rating (amps) ....................................................................................................................... 100
Voltage Rating (VAC) ........................................................................................................................ 250
Utility Voltage Monitor (fixed)
-Pick-up                             ...................................................................................................
70%
-Dropout                            ...................................................................................................
60%
Return to Utility                   .................................................................................................... approx. 13 sec.
Exerciser weekly for 12 minutes .................................................................................................... Standard
UL Listed ....................................................................................................................................... Standard
Dimensions (H” x W” x D”) ....................................................................................................... 26.5 x 12.5 x 7
Total of Pre-wired Circuits .................................................................................................................. 16
No. 15A 120V ................................................................................................................
5
No. 20A 120V ................................................................................................................
5
No. 20A 240V ................................................................................................................
1
No. 40A 240V ................................................................................................................
1
No. 50A 240V ................................................................................................................
1
Circuit Breaker Protected 
Available RMS Symmetrical
Fault Current @ 250 Volts .................................................................................................... 10,000
Mechanical Dimensions (in inches)
Current No. of 
Height
Width
Depth
Rating
Poles
H1
H2
W1
W2
100 UL Listed
2
26.5
29.25
8.14
12.5
7
W1
W2
H1
H2
Terminal Wire Ranges
ATS Rated Amps
Switch Terminal
Neutral Lug/Stud
Ground Lug
100A 2-Pole UL
1 x 1/0-12
1 x 3/8-16 Stud
1 x 2/0-14
Transfer Switch Features
• Electrically operated,
mechanically-held contacts for
fast, positive connections.
• Rated for all classes of load,
100% equipment rated, both
inductive and resistive.
• 2 pole, 250 VAC contactors.
• 160 millisecond transfer time.
• Dual coil design.
• Main contacts are silver plated
or silver alloy to resist welding
and sticking.
• Nema 1 enclosure is standard
on the 100 amp switch.
Conduit sizes 
vary depending 
on model #