Panasonic WJ-MPU955A Manual Do Utilizador

Página de 87
28
Connection with System Devices
In addition to the WJ-MPU955A, other system devices are
required in order to form the GX System.
■ System Controllers
A system controller is an operator console, and it provides
a user interface for operators to interact with the GX
System. The system can support up to 64 system con-
trollers.
● Ethernet-Based Controllers
To apply Ethernet communication, connect system con-
trollers to the CPU's Ethernet port through an Ethernet hub
in an IP-based local area network.
● Ethernet-Based Controller Setup
To add system controllers to the system in Ethernet com-
munication, add an entry to the system controller database
through the admin console. You need to assign a controller
ID for each controller, and enter the Ethernet address from
the bottom of each controller.
Note: Refer to the Admin Console User's Guide for details.
10BASE-T/100BASE-TX
SERIAL
2
1
OTHER
SYSTEM
DEVICE
SYSTEM
CONTROLLER
POWER
ON
AC IN
OFF
SIGNAL GND
System Controller 
(Ethernet)
WJ-MPU955A
Switching HUB
172.18.0.1
DC9V IN
MODE
DATA
SERIAL
CONTOROLLER
NO.
JOYSTICK
10/100 BASE-T
CAUTION
ATTENTION
CAUTION-
CONNECT TO
SPECIFED CLASS 2 POWER
SUPPLY ONLY. SEE MANUAL
Refer to the diagram.
CONTROLLER No.
Maintain the switch 
setting as “1”.
WV-CU
950
MODE
MODE
1
2
3
4
5
6
7
8
OFF
ON
Set as shown below.
0
9
8
7
6
5
4
3
2
1
■ Connections and Configura-
tions for Redundant System
● For Manual Switchover Operation
1. Connect the Ethernet cable between the SYSTEM
CONTROLLER ports of both CPUs.
(SERIAL ports are not used for MANUAL operation.) 
2. Set the REDUNDANT YES/NO selector to YES, and set
the REDUNDANT AUTO/MANUAL selector to MANUAL
for both CPUs.
Note: If the REDUNDANT YES/NO and AUTO/MANUAL
selector settings of both CPUs are mixed, the
redundant function does not work properly. In this
case, the ACTIVE indicator of either CPU blinks
fast (around 0.5 seconds on, around 0.5 seconds
off) during operation.
WJ-MPU955A
WJ-MPU955A
10BASE-T/100BASE-TX
SERIAL
2
1
OTHER
SYSTEM
DEVICE
SYSTEM
CONTROLLER
POWER
ON
AC IN
OFF
SIGNAL GND
10BASE-T/100BASE-TX
SERIAL
2
1
OTHER
SYSTEM
DEVICE
SYSTEM
CONTROLLER
POWER
ON
AC IN
OFF
SIGNAL GND
PC with 
Admin Console
Switching HUB
9 pin D-sub, female-female 
cross cable
(Not required for manual 
switchover operation)
Note: Secure the connector 
screws firmly to prevent cable 
disconnection.
1
2
3
4
5
6
7
8
Frame
1
2
3
4
5
6
7
8
Frame
Shield
WJ-MPU955A