SPECIFICATIONS
Wire Diameter Capacity .................................... .030 - 1/16" ALL Types
Wire Capacity .................................................... 12" Standard
(Insulated or Non-Insulated)
Power Input ....................................................... 42 VAC 50/60 Hz,
............................................................................ 150 Watts Peak (3 amps)
Weight ................................................................ 31 pounds
Shipping Weight ............................................... 36 pounds
For Use with these Lincoln Torches ............... K1589,K1590,K1591,K1592
Section 2
SUPPORT EQUIPMENT REQUIRED
C.V. or C.C. Power Source of Sufficient Capacity for Your Needs.
Regulated Gas Supply and Hoses.
Properly Sized Power Leads from Power Source to Wire Feeder and Ground.
Water Source and Hose Capable of Providing a Minimum of 1 qt/min. at 45
p.s.i
. when using water cooled torches.
Section 3
COOLANT RECOMMENDATIONS
1.  Use a name-brand additive which does not contain reactive sulphur or
chlorine and does not react with copper, brass, or aluminum.
2.  Check coolant periodically to remain within limits of the following:
A.  Coolant Flow rate - 1 quart/minute at 45 p.s.i.
B.  Resistivity - 10K ohms/centimeter
C.  Ph Range - 5.5-8.5
D.  Particle Size - .005"
Section 4
OPTIONAL ACCESSORIES
Replacement Plastic Guides for Slave Motor
Lincoln
MK Products
Inlet Guide
S23980-1
753-0062
Outlet Guide with Knob
S23980-2
003-0428
Section 5
INSTALLATION
5.1  LOCATION
The cabinet should be placed in a location where it can be protected from
damage.  Lead lengths and accessibility must also be considered when
installing the cabinet.