1.  Remove old showerhead. Clean pipe threads thoroughly.
2. Attach the flexible shower arm collar to the 
showerhead, being careful to align  
the threads.
3. While installing, support the showerhead and hold onto the  
nut rather than the cover. Turn only the nut to tighten.  
Do not twist the flexible shower arm covering  
during installation. (This could damage the  
covering and/or cause the product to  
malfunction.) Take care in aligning  
the nut to the shower pipe so you  
do not cross threads.
4. Tighten the shower nut onto the pipe 
securely by hand. Do not over  
tighten or use pliers.
5. Slowly turn on cold water and check for leaks. If leaks occur, retighten  
all connections.
6. Do not use excessive force in positioning the showerhead and/or arm.
7. If the showerhead is not maintaining its position, re-tighten the  
showerhead collar and shower arm nut.
Nut
Flow Regulator  
(black O-ring faces out)
Washer
Filter Screen
Waterpik
®
 showerheads are equipped with an OptiFLOW
®
 regulator that 
limits maximum water flow to 2.5 gallons per minute at 80 psi  
as mandated by U.S. federal law. 
In areas with extremely low water pressure, causing  
the shower water flow to be unsatisfactory, the  
flow regulator may be removed to improve  
the water flow in the showerhead.  
To remove, unscrew  
filter screen by turning  
counterclockwise.  
Remove regulator  
with needle-nose  
pliers and replace  
filter screen.
FN 20007764-F AB
Shower  
Arm Nut
Adapter
Spray Change 
Button
5’ hose
Instruction Manual
drenching rain
 
showerhead
Models:
CF-200
CF-201
CF-201C
CF-203C
CF-209C
CF-261
CF-263C
Limited Lifetime Warranty
Water Pik, Inc. warrants to the original purchaser of this product that 
it is free from defects in material and workmanship for as long as the 
original purchaser owns this product. Water Pik, Inc. will at our election, 
repair or replace any part of the product which in our opinion is defec-
tive, provided that the product has not been abused, misused, altered 
or damaged after purchase. (This includes damage due to use of tools 
or harsh chemicals.) In the event an item has been discontinued we will 
replace with what we deem to be the closest product. Water Pik, Inc. 
is not responsible for labor charges, installation, or other consequential 
cost. The responsibility of Water Pik, Inc. shall not exceed the original 
purchase price of the product. This warranty gives you specific legal 
rights. You may also have other rights that vary where you reside. Save 
your receipt as proof of purchase is required for warranty action. 
U.S. Patent Numbers: 5,865,378; 5,997,047 (Lic);  
6,164,570 (Lic); 6,626,210; 6,629,651;6,641,057; D440,641; 
D452,897; D485,887
Filter  
Screen
Flow Regulator
Hand-Held Installation
1.  Remove old showerhead. Clean pipe threads thoroughly.
2. Slightly loosen swivel collar on bracket.
3. Hand tighten pivot ball to pipe.
4. Hand tighten adaptor to showerhead.
5. Hand tighten hose to adapter and bracket.
6. Place showerhead in bracket.
Collar
Flexible Arm
Spray Change 
Button
Bracket
Flexible Installation
Your new showerhead will fit a standard 1/2” shower arm. Do not  
attach this product to a plastic shower arm since it may not provide  
adequate support.
Tools are not required. Do not use pipe tape or any other sealants when 
installing the showerhead. These materials are not necessary and may cause 
the nut to loosen prematurely. Hand tightening is sufficient to secure the 
shower thread. Make sure the washer is in the end of the nut.
Operation
To change settings, from 
either the full-body spray 
or the concentrated power 
spray, push the spray 
change button at the base 
of the showerhead so it 
extends to the opposite 
side of its current position.
Spray Change Button
Spray Change Button
Clean the filter screen at least once a year, or when you notice a drop in  
water pressure. To remove, unscrew the nut from the pipe. Remove the  
screen by turning it counter-clockwise (pliers may be used) and rinse.
If you remove the flow regulator, be sure you reinstall it with the black O-ring 
facing out.
• Cleaning is required when mineral deposits appear on the spray holes to 
maintain proper working conditions.
• Clean the flexible nozzles by rubbing with a finger or soft bristled toothbrush.
• Do not clean or rinse any part with harsh chemicals, heavy-duty cleaners or 