DC12V +
GND
8   7   6   5   4   3   2   1
15 14 13 12 11 10  9
16                    17
PIN Connection Application
Solder Side 
of DSUB 
15PIN
APPENDIX #2
APPENDIX #2
APPENDIX #2 
APPENDIX #2 
PIN CONFIGURATION
PIN CONFIGURATION
48
PIN
FUNCTION
DESCRIPTION
1
RS232-TX
DVR can be controlled remotely by the keyboard of PC by using RS-232 serial 
communication signals.
2
RS232-RX
DVR can be controlled remotely by the keyboard of PC by using RS-232 serial 
communication signals.
3~6
ALARM INPUT
To connect the wire from ALARM INPUT ( PIN 3 -- 6 ) to GND ( PIN 9 ) 
connector, DVR will start recording and the buzzer will be on. 
When “MENU -> CAMERA -> ALARM” is set to “Low” : When the alarm input 
signal is “ Low ”, the unit starts to record and buzzer.
When “MENU -> CAMERA -> ALARM” is set to “High” : When the alarm input 
signal is “ High ”, the unit starts to record and buzzer. 
7
EXTERNAL 
ALARM NC
Under the normal operation, COM connects with NC and disconnects from NO. 
But when any alarm is triggered, COM disconnects with NC and connects with 
NO.
Attention: The voltage restriction is under AV/DC 30V. 
8
EXTERNAL 
ALARM NO.
Under the normal operation, COM disconnects with NO. But when any alarm is 
triggered, COM connects with NO. 
Attention: The voltage restriction is under AV/DC 30V.
9
GND
Signal GND.
10
RS485-B
DVR can be controlled remotely by the keyboard of PC by using RS-485 serial 
communication signals.
11
RS485-A
DVR can be controlled remotely by the keyboard of PC by using RS-485 serial 
communication signals.
12~13
PIN OFF
14
ALARM RESET
Connecting the wire from ALARM RESET (PIN 14) to GND (PIN 9) connector 
will disable alarms. An external signal to ALARM RESET (PIN 14) can be used 
to reset both ALARM OUTPUT signal and DVR’s internal buzzer. When any 
alarm has been triggered, the signal becomes “Low”, and all alarm activities will 
be stopped. Under the normal operation, the signal remains “High”.
15
EXTERNAL 
ALARM COM
Under the normal operation, COM disconnects with NO. But when any alarm is 
triggered, COM connects with NO. 
Attention: The voltage restriction is under AV/DC 30V.
16~17
GND
Earth GND
When the magnetic contact is opened, the 
alarm will be triggered and the recording is 
on. At the same time, COM connects with 
NO and the siren with strobe starts wailing 
and flashing.
NOTE: Please go to MENU -> ADVANCE -> 
DETECTION -> DETECTION SETUP, and 
set ALARM to LOW on the local machine.
DC12V +
GND