Mitsubishi Electronics MR-J2S- B Manual Do Utilizador

Página de 236
12 -  16
12. OPTIONS AND AUXILIARY EQUIPMENT
(b) FR-BR resistor unit
[Unit: mm]
2      C
Control circuit
terminal
Main circuit
terminal
W1    1
Approx. 35
Approx. 35
204
Hanging bolt
C
C
W    5
For FR-BR-55K, a hanging bolt is placed
on two locations (Indicated below).
(Note)
(Note)
Note. Ventilation ports are provided on both sides and the top. The bottom is open.
Resistor unit
W
W1
H
H1
H2
H3
D
D1
C
Approximate
mass
[kg] ([lb])
FR-BR-15K
170 100 450 410
20
432 220
3.2
6
15 (33.1)
FR-BR-30K
340 270 600 560
20
582 220
4
10
30 (66.1)
FR-BR-55K
480 410 700 620
40
670 450
3.2
12
70 (154)
(c) MT-BR5- (H) resistor unit
[Unit: mm]
Resistor unit
Resistance
value
Approximate
mass
[kg] ([lb])
MT-BR5-55K
2.0
50 (110)
4   15 mounting hole
300
75
75
450
7.5
7.5
M6
M4
193
189
480
510
37
60
21
10
NP