•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Connections
Mode out +/– (1-4)
Active:
Short
Max. Drive current 500 mA DC.
   Relay output
Non active: Open.
Max. Voltage +24 V DC.
Call out +/–
Active:
Short
Max. Drive current 7 mA DC.
   Photo coupler output Non active: Open.
Max. Voltage +24 V DC.
Emergency input/Alarm input (1-16)/Recording/Clock adjust input
Active:
When terminals are short-circuited or “Low”
Level is applied.
Non active: Open.
Alarm Output
Active:
“Low Level”    Max. Drive current 7 mA DC.
Non active: Open.
Max. Voltage +24 V DC.
Alarm recording connection
The diagram below shows an example of connection for alarm signals corresponding to sensor number 1.
ALARM SWITCH
RS-232C
GND
ALARM OUT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ALARM IN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
<Interface circuit inside the unit>
5V
5V
10k
Ω
22k
Ω
Input
terminal
0.047
µF
GND
EMERGENCY/ALARM IN/REC/
CLOCK ADJ Input terminal 
• Input Circuit
4.7k
Ω
<Interface circuit inside the unit>
MODE OUT 1 - 4 Output terminal 
• Output Circuit
MODE OUT
<Interface circuit inside the unit>
CALL OUT terminal
CALL OUT GND terminal
CALL OUT Output terminal 
• Output Circuit
<Interface circuit inside the unit>
Output terminal
GND terminal
ALARM OUT Output terminal 
• Output Circuit