Q-See QSD2308L Manual Do Utilizador

Página de 80
QSD2308L/QSD2316L DVR User’s Manual 
 
37
 
Here users can set sensor type, alarm trigger and alarm time. The following 
are the definitions of each option. 
Device type: NC and NO (Normal Close and Normal Open). Set the value 
according to the alarm signal level of the sensors. 
Enable: Enable sensor alarm. 
 
Trigger: Set alarm output, recording channel and speed dome linking. Click 
Set button, a window will appear shown as Fig 4.10 Alarm Out Configuration. 
 
Fig 4.10 Alarm Out Configuration 
Alarm out: Set relay alarm out channel. You can select any alarm 
channels. 
To record: Set recording channels. You can select any record channels. It 
will record on the cameras you choose here when alarm triggered. 
Buzzer: Enable on board buzzer for alarm. 
To P.T.Z CH: Set linked preset and cruise for alarm. You can select any 
channel and multi channels as linked channels. 
 
Alarm in hold time(S): The interval time between two consecutive sensor 
alarm events. If a second alarm is detected within Hold time, it is recognized 
as a continuous alarm. If a second alarm is detected after hold time, the 
second alarm and the previous one are recognized as two different alarm 
events. 
Alarm out hold time(S): Set relay alarm out time after alarm is triggered. 
Buzzer hold time(S): set on board buzzer time after alarm is triggered.