Toshiba KV-HD01A Manual Do Utilizador

Página de 56
 
35
ALM TYPE:   
The ALM TYPE option is used to set a type of alarm input corresponding to the sensor signal in 
use. 
 NO: Normally Open. This is to be used with the type of alarm sensor, whose contact   
 
 remains open in normal conditions and closes in case of activation. 
 NC: Normally Close. This is to be used with the type of alarm sensor, whose contact   
 
 remains closed in normal conditions and opens in case of activation. 
 
ALM DURATION:   
The ALM DURATION option is used to set the alarm record mode to record for a certain duration 
after the alarm has been deactivated. You can select one of the six following options: 0 SEC, 
30SEC, 1 MIN, 5 MIN, 10 MIN, and NON-STOP. 
         
         
D uration
Set ting
Alarm
activated
Alarm
deactivated
Reset
Alarm recording
N on-Stop
Alarm
activated
Alarm
deactivated
D uration
Alarm recording
Duration
 
 
 
PRE- ALARM:   
The PRE-ALARM option is used to determine that images prior to an alarm will be recorded into 
the hard-disk drive. If the alarm-recording rate is set to 60F/S, when an alarm is being triggered 
the device will record the image prior to the alarm for 3 seconds. If one of the other 
alarm-recording rates is set, the pre-alarm image recording will be extended to 5 seconds.   
 
ON: Enables pre-alarm recording. 
 
OFF: Disables pre-alarm recording.