Sanyo DSR - 300 Manual Do Utilizador

Página de 136
RS-232C/RS-485 SET
2
70
English
(when optional interface board is installed)
SE
TTIN
GS <MAIN
 MENU 2>
Connect the digital video recorder’s RS-485 (A, B) control 
terminals in series to the system controller, multiplexer, 
digital video recorder, or similar device.
4
Select “RS-485” and press the [ ] 
button.
The cursor moves to “DATA SPEED”.
5
Press the [ ] button, then the [
] or 
[
] button to set the data speed, and 
press the [ ] button.
Possible selections: 2400, 4800, 9600, and 19200
(Example: 19200)
6
Press the [ ] button after moving the 
cursor to “STATUS INFO” and press the 
[
] or [
] button to set “ON”. Then 
press the [ ] button.
[Settings] (‹ indicates default setting.)
7
Press the [ ] button after moving the 
cursor to “ALARM INFO” and press the 
[
] or [
] button to set “ON”. Then 
press the [ ] button.
[Settings] (‹ indicates default setting.)
8
Press the [ ] button after moving the 
cursor to “ADDRESS” and press the 
[
] or [
] button to change the 
setting.
[Setting conditions]
z
Addresses between “0” and “127” can be set for this 
unit.
9
Press the [EXIT/OSD] button.
The display returns to the normal screen.
z
Addresses must not be duplicated when a number of 
different digital video recorders are being connected.
Also, turn on the termination switch for the last digital 
video recorder in the connection sequence.
When RS-485 is selected
Setting
Description
‹
ON
Status information is transmitted.
OFF
Status information is not transmitted.
RS-485
RS-485
Setting
Description
‹
ON
Alarm information is transmitted.
OFF
Alarm information is not transmitted.
e00_l8had_us_7.book  Page 70  Wednesday, March 10, 2004  2:47 PM