CNA configuration and deployment
360 Avaya Application Solutions IP Telephony Deployment Guide
 
Configuring CNA
Basic configuration
Configuring Virtual Module Interfaces
Avaya CNA Ethernet interfaces need to be associated with an Ethernet interface and a physical 
connection to the network. Once the system has booted and all of its necessary ports are 
connected to the network, a terminal or workstation can be connected to the serial console port 
on the CNA system.
Using privileged-level access, the user should enter the configure terminal command.
Ethernet Interfaces on Modules
To create an interface, enter the interface command while in config mode. Enter 
fastethernet
 as the type argument. The num argument is 0, while the port arguments 
correspond with the labeled Ethernet ports on the system. 
To assign an address to the interface, enter the ip address command with a valid IP address 
and mask from your network address space. End the configuration of this interface with the end 
command. E.g., for the management interface, enter the command to configure Ethernet 0. 
Ustat modules will also have to be referred to inside the interface module. (Ustat modules will 
be defined on Page 9). 
interface fastethernet 0/0
ip address 176.16.6.4 255.255.255.224
module ustat provider_1
module ustat provider_2
module ustat provider_3
end
Default Gateway
A default route needs to be defined for the system so that it knows how to communicate with the 
rest of the network:
ip route 0.0.0.0 0.0.0.0 172.16.6.3