Connecting & Checking Two-Wire Telephones 
All two-wire devices (POTS) should be tested according to the manufacturer's instructions 
before connection to the IP Office system. Connect the two-wire device and make a test 
call. 
 
Power Fail Telephones and Sockets 
All power fail sockets (on IP400 Analog Trunk 16 modules only – see page 27) must be 
tested. 
To test a power fail socket : 
1.  Locate the socket and check that it is clearly labeled as a power fail socket. 
2.  Connect a telephone to the socket. 
3.  With power to the IP Office system switched on, make a test call. 
4.  Switch the power to the IP Office system off and again make a test call. 
5.  Switch the power to the IP Office system back on again. 
6.  Repeat the test for any other power fail sockets. 
Note:   Where E911 statuary requirements for discrete location identification of a power 
fail phone are required on the transmitted CLI, ensure that the relevant 
installation programming is completed.