Lucent Technologies 555-661-150 Manual Do Utilizador

Página de 360
MERLIN LEGEND Communications System Release 6.1
Network Reference  
555-661-150  
Issue 1
August 1998
Troubleshooting 
Page 6-31
No Message Waiting Light Update 
6
Some of the problems described in this section can occur when a system 
manager makes a change in a networked system’s local dial plan, 
non-local dial plan, switch identifier, or DS1 Switch Type setting. Ensure 
that your private network system forms are kept up to date and that 
changes are cleared with the coordinating system manager.
NOTE:
If there is an alarm on the CPU board and Message Waiting light updates 
not delivered is the only obvious problem, check the possible causes in this 
section before calling the Lucent Technologies helpline.
Possible Cause 1: The UDP at the VMI hub system for voice messaging 
subscribers is programmed incorrectly.
What to Do: Check the programmed routing for the VMI conversion number:
Verify the ranges for the non-local subscribers.
Verify that the pattern for each range has routes assigned.
Verify that each route has pools assigned with the same type of trunks in 
each pool.
Possible Cause 2: All programmed available routes for the call are busy. 
What to do: Check that the pattern assigned to the VMI conversion number 
includes routes that include pools that have a sufficient number of trunks to 
handle the call volume. 
If you’re not sure of the pattern number being used to route calls in your 
local system, see 
page 3
.
To add different routes that can handle the call, consult the coordinating 
system manager and see 
 or 
“Centralized Voice Message” in Chapter 4 of 
System Programming. 
If the routing is correct and enough routes are included in the pattern, but 
the problem persists, check if PRI lines are used. If they are, check the 
error log for D-channel inoperative and loss of signal alarms indicating lines 
are inoperative. If the D-channel inoperative alarm has occurred, check the 
CSU/DSU associated with the line for correct programming. If the loss of 
signal alarm has occurred, check for open cables, etc. If these conditions 
are not present, go to Possible Cause 4.
Possible Cause 3: Not enough trunks are assigned to the pools for UDP routes. 
What to Do: Consult System Form 2c, System Numbering: Line/Trunk Jacks to 
determine the assignments. To see a report of pool assignments, select the 
3ULQW
 
option on the System Programming menu and then choose
7UXQN,QIR
and
*HQHUDO
.