Peerless Industries KX-TDA15 Manual Do Utilizador

Página de 380
1.1 Incoming Call Features
34
Feature Guide
1.1.2.2
Internal Call Block
Description
Internal calls can be restricted on a COS basis. Each COS of the caller can enable or disable 
this feature for each COS of the called party.
[Programming Example]
Explanation:
a) COS 1 can make calls to all extensions.
b) COS 2 can make calls to COS 1 only. (COS 2 cannot make calls to COS 2.)
c) COS 3 can make calls to COS 3 only.
Conditions
Restricted extension numbers cannot be the parameter of the feature settings (e.g., 
Walking Extension).
All extensions can make an Operator Call (
 2.2.5 Operator Features) regardless of the 
Internal Call Block.
Caller
Called Party
COS 1
COS 2
COS 3
...
COS 1
COS 2
COS 3
:
:
:
:
:
: Block
COS 1
Extn. 100
Extn. 101
COS 2
Extn. 102
Extn. 103
COS 3
Extn. 104
Extn. 105