Patton electronic SmartNode 4110 Series Manual Do Utilizador

Página de 664
Using the AdventNet SNMP utilities
278
SmartWare Software Configuration Guide 
25 • SNMP configuration
-
Message that by default has the object identifier format (sequence of numeric or textual labels on the SNs 
along a path from the root to the object) of the trap if any, or it is blank.
The details of the traps can be viewed by clicking the Trap Details button or right click the trap in the trap 
table and select the option View Trap Details
 show the screen of such a trap details window.
Figure 43. AdventNet Trap Details window of TrapViewer 
The various details available in the Trap Details window are listed in 
Table 12. Details available in the Trap Details window 
Trap Details
Description
TimeStamp
The TimeStamp is a 32-bit unsigned value indicating the number of hundredths-of-a-second 
that have elapsed since the (re)start of the SNMP agent and the sending of the trap. This 
field shows the value stored in the MIB-II sysUpTime variable converted into hours, minutes 
and seconds.
Enterprise
This field shows the OID of the management enterprise that defines the trap message. The 
value is represented as an OBJECT IDENTIFIER value and has a variable length.
Generic Type The Generic type value is categorized and numbered 0 to 6. They are 0-coldStart, 1-warm-
Start, 2-linkDown, 3-linkUp, 4-authenticationFailure, 5-egpNeighborLoss. The trap type 
value 6 is identified as enterprise-specific value. This field shows the value based on the 
type of trap.
Specific Type The specific trap type indicates the specific trap as defined in an enterprise-specific MIB. If 
the Generic type value is 6 then, this field shows a value greater than 0. If the generic type 
value is a value other than 6, then the field shows a value 0. This field can have values 
from 0 to 2147483647.
Message
This is a text field. By default, this field will always contain the Varbinds in the Trap PDU. 
This can be substituted with text.
Severity
This field shows the Severity or the intensity of the trap. They could be 0-All, 1-Critical, 2-
Major, 3-Minor, 4-warning, 5-Clear and 6-info.