Patton electronic SmartNode 4110 Series Manual Do Utilizador

Página de 664
Gateway configuration task list
552
SmartWare Software Configuration Guide 
45 • H.323 gateway configuration
Mode: Gateway H.323
Step
Command
Purpose
1
node(gw-h323)[h323]#h235security master-
password 
master-password
Sets the master password (32 hex digits, 0–9, 
A–F) with which the H.235 password is 
decrypted.
Note
Configure the master password only 
over secure links (e.g. in LAN envi-
ronments only or with serial connec-
tion), which cannot be wiretapped.
2
C:\getcryptopassword 
h235-password mas-
ter-password
Generates H.235 password by means of the 
master password with the encryption tool.
3
node(gw-h323)[h323]#h235security pass-
word 
h235-password encrypted
or
node(gw-h323)[h323]#h235security pass-
word 
h235-password
Sets the password used for crypto token cal-
culation. The password is entered encrypted. 
The password to be entered is the output of 
the tool getcryptopassword.exe.
Configures the password used for crypto 
hashed token calculation. The password is 
entered in clear text (min. 1, max. 12 alpha-
numeric characters).
Note
Do not use this command over inse-
cure links (subject to wiretapping). If 
you enter the password as clear text, 
you don’t need to configure a 
master-password.
4
node(gw-h323)[h323]#h235security time-
window 
time-window
Sets the time window used for timestamp com-
parison by H.235. If a received H.323 mes-
sage with H.235 crypto token has a timestamp 
outside the time window (relative to the local 
time) the message is refused.
5
node(gw-h323)[h323]#h235security ver-
sion {v1 | v2}
There are two H.235 versions, use v1 if v2 
does not work. In v1, sender-id and general-id 
must not be specified.
6
node(gw-h323)[h323]#h235-security ras-
auth-int-rx [
<msg>]
or
node(gw-h323)[h323]#no h235-security 
ras-auth-int-rx [
<msg>]
Enables or disables H.235 security for received 
RAS packets. msg is the message type.