Peerless Industries KX-TDA30 Manual Do Utilizador

Página de 380
2.4 Fault Recovery/Diagnostics
312
Feature Guide
2.4
Fault Recovery/Diagnostics
2.4.1
Power Failure Transfer (KX-TDA30/KX-TDA100/KX-
TDA200 only)
Description
When the power supply to the PBX fails, specific SLTs and/or ISDN terminal devices are 
automatically connected to specific trunks (Power Failure Connections). The PBX will switch 
from normal operation to the Power Failure Connections, and all existing conversations will be 
disconnected.
Only the trunks handled by Power Failure Connections can be used during a power failure.
Conditions
[General]
Only trunk calls can be made during a power failure. All other features do not work.
DC Power Source
If the DC power is available from backup batteries, even if the AC power fails, the PBX will 
remain fully operational.
[KX-TDA100/KX-TDA200]
The analogue trunk cards and extension cards and the number of ports which can be used 
for Power Failure Connections are as follows:
Trunk Cards: LCOT16 (four ports), LCOT8 (two ports), and LCOT4 (two ports)
Extension Cards: MSLC16 (four ports), SLC16 (four ports), DHLC8 (two ports) and SLC8 
(two ports).
To each trunk card, connect only one extension card.
Note
Power Failure Connections between analogue trunk cards and extension cards should be 
done as per system programming so that conversation is maintained when the power is 
restored and the MPR is recovering.
The BRI8 (one port) and BRI4 (one port) cards can also be used for Power Failure 
Connections. For details about Power Failure Connections, refer to the Installation Manual.
[KX-TDA30]
Ports 1 and 2 of the LCOT card installed in the least slot number and ports 1 and 2 of the 
Super Hybrid ports can be used for Power Failure Connections.
Note
The Power Failure Connections between the LCOT card and Super Hybrid ports are 
automatically kept so that the conversation is maintained when the power is restored and 
the Main Board is recovering.