2.4 Fault Recovery/Diagnostics
Feature Guide
315
2.4.3
Local Alarm Information
Description
When a PBX error occurs and the PBX detects it, the System Alarm button light on the PT of 
an extension, which is allowed to use this feature through system programming (a maximum 
of two extensions per PBX), turns on red. Pressing the button will show the error number on 
the display. If multiple errors occur, the error number will be displayed in order of highest priority 
to lowest. The System Alarm button light turns off automatically after all error numbers have 
been displayed.
For details about the errors and their solutions, refer to the Installation Manual.
[Error Example]
[Explanation]
Conditions
System Alarm Button
A flexible button can be customised as the System Alarm button.
If an extension allowed to utilise this feature uses a PC Console or PC Phone, the alarm 
information will be displayed on the PC.
If an extension allowed to utilise this feature uses a PC Console or PC Phone, the alarm 
information will be sent to the preprogrammed party via the PC Console or PC Phone. The 
PC Console and PC Phone use e-mail to send the information.
The alarm information will be recorded on the SMDR, if enabled through system 
programming.
The PBX can be automatically diagnosed at a preprogrammed time everyday.
Number in the 
Example
Item
Description
(1)
Error Code
Shows three-digit error code.
(2)
Sub Code
Shows five-digit sub code (XYYZZ).
X: Cabinet number (1–4)
YY: Slot number (00–11)
ZZ: Physical port number (01–16)
ERR #100 (10000)
(1)
(2)