Avaya 40DHB0002USCL Manual Do Utilizador

Página de 70
Expansion Modules 
IP400 Analog Trunk 16 - Page 31 
IP400 Analog Trunk 16 
Front View 
Analog Trunk Ports 1-8
 
Unit Status LED
Red = Alive but not initiated 
Green = Running OK
 
Analog Trunk Ports 9-16
 
 
Port connections 
•  Analog Trunk Ports 
These ports are used for connection to standard analog trunks (loop start or ground start). Using 
standard structured wiring, these RJ45 ports can be extended to the required trunk sockets. 
Trunk ports 1 and 2 are, in the event of power failure, automatically switched to PF1 and PF2 
respectively on the rear of the unit (see below).  
 
Rear View 
 
Expansion Port
DC Power I/P Socket 
EXPANSION
 
DC I/P 
 -  C  +
 
 24V DC 
        2A
 
PF2
 
PF1
 
Power Fail Trunks 1 & 2
 
Protective Earth Point
 
 
Port connections 
•  Expansion Port 
Used to connect the Analog Trunk Expansion Module an Expansion Ports of an IP400 Office 
platform. 
•  DC Power I/P Socket 
Socket for the external 24V DC unregulated power supply (supplied with kit). 
•  Protective Grounding Point 
Within the USA a protective grounding must be permanently fitted. Connection of this protective 
grounding requires the use of suitable tools and must be connected at both ends before 
•  Power Fail Trunks 
These two ports must be set and connected to Loop Start trunks only. POTs plugged into these 
two sockets are mapped to trunk ports 1& 2 such that, in the event of a mains power failure, PF1 
and PF2 can operate as 'hot lines' to the emergency services (e.g. 911, etc). 
 
Cables 
IP400 Analog Trunk 16 is supplied with one blue Expansion Interconnect cable. For Port Pinouts and 
IP Office Installation Manual 
Expansion Modules - Page 31 
40DHB0002USCL – Issue 7 (09/25/2002) 
 IP400 Analog Trunk 16