Avaya 555-233-116 Manual Do Utilizador

Página de 246
DEFINITY INADS
Issue 4   October 2002
181
555-233-116
Administration
NOTE:
Add 2 pauses in front of the dial string when using cut-through trunks. 
Pauses are not required if using ARS.
1. Type change system-parameters maintenance and press 
Enter
.
2. For high reliability systems, in the 
see interchange: 
field, type daily 
and press 
Enter
. This is done in case 1 of the connections between the 2 
TN1648B circuit packs is down. This assures that within 24 hours the 
working connection is available to report alarms.
3. Type add station number or next and press 
Enter
.
4. In the 
Type
 field, enter 500 (rotary analog telephone).
5. In the
 Port
 field, enter the port number for this line.
6. For high reliability systems, repeat the above steps for the second analog 
line. Administer the 2 stations as part of a TEG (terminating extension 
group).
a. Type add term-ext-group number or next and press 
Enter
.
b. In the 
Group Extension
 field, enter the TEG extension number.
c. In the 
Coverage Path
 field, enter the coverage path number.
d. Enter the Group Member Assignment station numbers.
e. Press 
Enter
 when finished.
Partner installation
The PARTNER system connects the INADS port to an outgoing central office 
(CO) line and is programmed to seize the outside line when INADS seizes an 
inside PARTNER station line. 
There are 2 types of PARTNER platforms:
PARTNER Atlas platforms with U.S. firmware and a wide input power 
supply (WIPS) that allows a universal power supply. The Spain platform 
conforms to the United States/Atlas platform
European platforms that focus on eastern Europe and the United Kingdom
The installation procedure describes the 2 types of PARTNER platforms with or 
without power fail transfer.