DEFINITY INADS
555-233-116
184
Issue 4   October 2002 
High reliability
Be sure that the TN1648B SYSAM circuit packs are located in different DEFINITY 
cabinets or processor carriers.
1. Bridge the 2 INADS tip/ring ports. A 258A adapter may be used. 
2. Connect the bridged INADS tip/ring port to a PARTNER station port.
INADS connection without power fail transfer
!
CAUTION:
Check local regulations regarding this connection method.
In this configuration (
), the INADS line and the emergency telephone 
extension are bridged together. If this connection method is not allowed, do not 
connect the INADS port to station 10.
Figure 43.
INADS connection (all platforms)
1. PARTNER system
2. MLS12D telephone for programming
3. Standard RJ-45 telephone cord
4. 103A or modular wall jack
5. Dial tone from the CO or a switch 
extension
6. Main distribution frame
7. PSTN
8. B25A 25-pair cable
9. AUX connector (use wire pair 50,25, tip 
and ring)
10. Avaya Media Server or Gateway PPN
cydf206b RPY 021998