External ringing
Issue 4   October 2002
205
555-233-116
External ringing
Connections for external ringing are at an information outlet. The system side of 
the main distribution frame (MDF) is connected to a TN2183 (or equivalent) 
analog line circuit pack in an MCC1, SCC1, CMC1, or G600 Media Gateway.
NOTE:
Up to three devices can be connected to one analog line circuit pack port. 
This does not apply to the G700 Media Gateway.
1. Wire the ringing device to the information outlet.
2. Administer the switch for the new equipment.
Queue warning indicator
The connections for the queue warning indicator are the same as external ringing. 
An AC indicator (light) such as a 21C49 can be used in a Uniform Call 
Distribution/Direct Departmental Calling (UCD/DDC) queue. The light is 
connected to an information outlet. The system side of the MDF is connected to 
an analog line circuit pack located in a port carrier.
NOTE:
This does not apply to the G700 Media Gateway.
1. Wire the queue warning indicator to the information outlet.
2. Administer the switch for the new equipment.