To change the operating mode of the 7400A from DCE to DTE (or vice versa), you 
change the position of a small circuit board (the Electronic Industries Association 
connector board) inside the case. See 
 and proceed as follows.
!
WARNING:
Electrostatic discharge can severely damage sensitive electronic circuits. 
Before handling any electronic hardware, be sure to wear a grounding wrist 
strap or other static-dissipating device. Do not touch exposed circuitry or 
semiconductor chips.
1. Unplug the data module from the power receptacle.
2. Remove the access panel on the top of the case by grasping the rear lip of 
the panel and pulling sharply upward.
3. While facing the front of the data module, locate the small EIA connector 
circuit board. It sticks up vertically, and a large, silver arrow on the main 
circuit board points to it.
Figure 11.
Data module mode selector
4. Note the three letters engraved in the upper lefthand corner of the EIA 
connector board. Data modules ship from the factory with board inserted 
with  “DCE” in the upper left corner. 
1. 7400A data module 