Connect data modules
Issue 4   October 2002
93
555-233-116
Configuring the 8400B Plus data module
 shows the rear of a 8400B Plus asynchronous data module. The unit 
provides integrated voice and data communications over standard, 2-wire, 
twisted-pair circuits within 2000 ft. of an DEFINITY. The unit can emulate a 
Hayes-compatible interface for standard personal computer (PC) communication. 
The options for the 8400B Plus are set from the rear panel interface.
Figure 17.
8400B Plus data module 
Installing required configuration equipment for the 8400B
Before you can enter configuration commands, you must first connect a terminal 
or a PC with a keyboard, monitor, and terminal-emulation software to the data 
module. Proceed as follows.
1. Connect one end of an RS-232 cable to an RS-232, serial-communications 
port (often called a COM port) on the terminal or PC. 
2. Connect the other end of the RS-232 cable to Port 1 of the data module
3. If you are using a PC, start your terminal  emulation software.
Selecting 8400B options
On the 8400B data module, all configuration options are enabled by default. You 
configure the 8400B by disabling options with a code that you enter in a memory 
register (S24) in the data module. Consult the table below, and perform the steps 
that follow. 
Table 12.
Codes for disabling default settings of the 8400B data module
Default setting
Disabling code
With Telephone
1
US Companding
2
Telephone Provides Dialing
4
Continued on next page