Data modules and asynchronous data units
555-233-116
98
Issue 4   October 2002 
Asynchronous data units (ADU)
ADUs are used with Data Line circuit packs to connect peripherals, such as 
printers, data terminals, fax equipment, and call-detail recording equipment to the 
DEFINITY
 shows a typical Z3A2 ADU assembly (without a cable).
NOTE:
Data modules, PGATE boards, printers connected through data modules, 
SATs connected through data modules, and anything related to the X.25 
connectivity protocol are not supported on the S8300 or S8700 Media 
Server platforms.
Add a female-to-male EIA-232 cable (shown) to make a Z3A1 ADU 
assembly. 
Add a female-to-female EIA-232 cable (not shown) to make a Z3A4 ADU 
assembly.
Figure 19.
Z3A2 Asynchronous Data Unit (ADU)
Refer to the tables in 
, for the 
pinouts of the TN726B data line circuit pack and TN2183 analog line circuit pack 
(or equivalents) in the cabinet.
1. Z3A2 ADU
2. 25-pin male D-connector (EIA-232-D) to 
DTE
3. Wall jack connector (to data line circuit pack 
or analog line circuit pack or equivalent)
4. Telephone jack (to analog telephone)
5. Originate/disconnect jack
6. Female connector on EIA-232-D cable
7. Male connector on EIA-232-D cable
adu KLC 053196