Additional asynchronous features
  
 
Voice call origination
By using a special cable, the MCA can communicate with two DTEs at the same 
time. The primary channel is the main communication channel offering MCA 
features. The second channel can respond to Voice Call Origination commands 
(VCO) only. This provides the ability to make a voice call across the second 
channel while simultaneously using the primary channel to transmit or receive 
high speed data. Below is the pinout list to connect the second channel.
Note: 
The VCO baud rate is 2400.
RS-232 pin
V.35 Pin
TxD
14
18
RxD
16
21
Gnd
7
7