Sterling 882.00249.00 Manual Do Utilizador

Página de 70
2–Pump 12-Station Controllers 
Chapter 6: Troubleshooting 
48 
 WRITING PARAMETERS
TO FLASH-PLEASE WAIT
 
    SAVING BACKUP
TO FLASH-PLEASE WAIT
 
Controller Recovery using Flash Memory Technology 
It is possible for a write error to occur while information is being saved in the controller’s 
memory. If this occurs, the system always saves a backup of the data. 
To recover from a write failure: 
•  Shut off the controller, wait 15 seconds, then restart the controller. 
The boot sequence detects the write error and attempts to restore the 
backup file. 
It is also possible, although rare, that the backup and original file could both become corrupt. 
If this occurs, then reset the controller to factory default parameters before proceeding. 
However, all parameters you’ve previously stored are lost and you’ll need to set up the 
controller from the beginning. You should record what settings you use in the controller 
system if this occurs.
 
The following screens display while the controller writes to flash memory. Again, do not 
cycle power
 while these two screens display. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Note:  The controller needs about 30 seconds for saving to flash 
memory. If the controller doesn’t clear this display within 60 
seconds, you may need to cycle power. This rare type of problem 
is caused by a write failure not detected by the controller. This 
rare condition usually requires a complete factory default reset 
for full recovery.