Sterling 882.00722.00 Manual Do Utilizador

Página de 60
 
Chapter 3: Installation 
35 of 60 
 
 
Alarm Setup 
This screen allows the operator to configure the alarm settings for the rate monitor. To 
configure the alarms do the following: 
6.  Enter the Setup Menu. 
7.  Once in the Setup menu, press “Alarm Setup.”  This will take you to the “Alarm 
Setup” screen. 
Figure 18: Alarm Setup Screen 
 
 
 
 
 
8.  Press the “Done” key at the bottom to exit this screen. Min/Max Speed Limits restrict 
the usable gravimetric range that the GH will permit in order to continue gravimetric 
measurement.  If the system becomes unstable for more than the “System unstable 
alarm time” then an alarm will notify the operator.  The Hopper% for low level 
should always be set below the reload percentage (hopper setup page) and the 
Hopper% for no material alarm should always be set below the low level %. 
Network Setup 
The rate monitor’s IP is the address of this rate monitor on a network. The rate monitor is 
factory set up with an IP of 192.168.0.150 with a default subnet mask of 255.255.255.0. 
In order to change the values, enter the Setup menu, press the “Network Setup” button and 
change the values accordingly. Then the “send Ethernet config to module” button must be 
pressed when changes are complete. 
The “COEXPERT COM DISABLED” button is not used on a GH-M rate monitor.  This 
parameter is automatically configured if a COEXPERT AB system exist.  Otherwise it should 
always remain disabled! 
 
Figure 31: Ethernet Setup Screen 
 
Change monitor’s IP 
Address and Subnet 
Mask 
Go back to Setup 
Directory 
Enable or Disable 
the Ethernet 
Module
 
Configurator 
Change the Alarm 
Silence Display 
Changes weigh hopper 
weight for no material
 
alarm. 
Disable for GH-M, 
GH-F, or GH without 
Coexpert AB