American Dryer Hand and Hair Dryer Folheto
Note:
Automatic
dryers
are
not
recommended
for
hair
drying
use.
1.
Removal
of
cover:
A)
Remove
special
allen
screw
using
wrench
supplied.
B)
To
remove
cover
, place
a
hand
on
each
side
of
cover
and
pull
bottom
toward
you
about
1/4
inch,
then
push
cover
up
toward
top
of
dryer
,
releasing
cover
from
mounting
plate
latch.
Lift
cover
of
f mounting
plate
by
pulling
forward
at
the
bottom
and
upward
at
the
same
time.
DO
NOT
FORCE
COVER
OFF
.
2.
REMOVE
(2)
bolts,
washe
rs
&
nuts
from
lower
mounting
holes
of
automatic
dry
-
ers. 3.
Dryers
should
be
placed
at
least
2
feet
(61cm)
apart
and
at
least
12”
(30cm)
from
washbasin.
Do
not
install
dryer
over
washbasin.
Automatic
dryers
should
be
at
least
18”
(46cm)
above
any
projection
which
may
interfere
with
the
operation
of
the
automatic
sensor
.
Hold
the
backplate
to
the
wall
at
the
suggested
mounting
heig
ht.
Measure
from
bottom
edge
of
backplate
to
the
floor
(Ref.
Dimension
“A”
Fig.
1)
DR-
Hand
Dryer
40”
(102cm)
38”(97cm)
28-38”(71-97cm)
32”
(81cm)
DR-N
Hand
Dryer
42”
(107cm)
40”(102cm)
30-40”
(76-102cm)
34”
(86cm)
DR-NH
Hair
Dryer
72”
(183cm)
68”(173cm)
46-68”(1
17-173cm)
52”(132cm)
4.
Mark
the
locations
of
the
four
mounting
holes
and
the
conduit
entrance
location
on
the
wall.
(The
conduit
entrance
is
the
proper
hole
diameter
for
1/2
inch
(13mm)
conduit.)
5.
Fasten
the
backplate
to
the
wall
where
previously
marked.
RECOMMENDA
TION:
W
ood
wall
-
No.
16
(M8)
wood
screws,
2
3/4”
(70mm)
long
Cement
or
brick
-
1/4”
(M6)
stud
expansion
bolts,
3”
(76mm)
long
Holl
ow
wall
-
1/4”
(M6)
toggle
bolts,
length
depends
on
wall
thickness
6.
Run
service
wire
to
the
dryer
location
and
connect
to
the
terminal
block.
IMPOR
TANT
: All
units
must
be
supplied
with
3
wire
service.
Use
No.
12
wire
or
larger
, as
required
by
local
electrical
code.
The
ground
wire
must
be
connected
to
the
dryer
backplate.
Unit
must
be
installed
by
a
qualified
licensed
electrician.
C
ONNEC
t
tO
A
DED
iCA
tED
C
iRC
uit
NO
t
tO
E
xCEED
20
AM
ps.
Dryers
located
in
shower
rooms
or
other
wet
locations
should
be
equipped
with
ground
fault
interrupter(s
).
7.
Care
full
y
replace
the
cover
using
tamper-proof
bolt
supplied.
Be
careful
not
to
damage
circuit
board
or
sensor
. Apply
a
bead
of
caulk
around
edge
of
cover
to
wall.
OWNER’S
MANUAL
“DR
” HAN
D
AND
H
Ai
R
DR
YERS
F
o
r
I
ns
ta
ll
at
Io
n
o
r
s
er
vI
ce
a
ss
Is
ta
nc
e
P
le
as
e
c
al
l
(734)
421-2400
o
r
Email:
sales@a
mericandryer
.com
I
m
Po
rt
an
t
:
H
av
e
M
o
de
l
&
S
er
ia
l
N
o
. r
ea
dy
m
o
de
l
#______
s
er
Ia
l
#______
MEN
WOMEN
Dis
ABLED
CH
iLDREN
(depends
on
age)
iN
st
ALLA
ti
ON
iN
st
Ru
Cti
ON
s
DISCONNECT
POWER
BEFORE
INST
ALLING
DESUNA
LA
ELECTRICIDAD
ANTES
DE
HACER
REP
ARACIONES
W
ARNING:
AMERICAN
DR
YER,
INC.
12932
FARMINGT
ON
ROAD,
LIVONIA,
MI
48150,
U.S.A.
Telephone
(734)
421-2400
•
Fax
(734)
421-5580
www
.americandryer
.com
• Email:
sales@americandryer
.com
Rev
. September
2006