American Dryer Hand and Hair Dryer Folheto

Página de 2
Note:
 Automatic 
dryers 
are 
not 
recommended 
for 
hair 
drying 
use.
1. 
Removal 
of 
cover:
   
 A) 
Remove 
special 
allen 
screw 
using 
wrench 
supplied.
   
 B) 
To 
remove 
cover
, place 
hand 
on 
each 
side 
of 
cover 
and 
pull 
bottom
   
   
  toward 
you 
about 
1/4 
inch, 
then 
push 
cover 
up 
toward 
top 
of 
dryer
,
   
   
  releasing 
cover 
from 
mounting 
plate 
latch. 
Lift 
cover 
of
f mounting 
plate 
by
   
   
  pulling 
forward 
at 
the 
bottom 
and 
upward 
at 
the 
same 
time. 
DO
 NOT
   
   
  FORCE
 COVER
 OFF
.
2. 
REMOVE
 (2) 
bolts, 
washe
rs 
nuts 
from 
lower 
mounting 
holes 
of 
automatic 
dry
-
ers. 3. 
Dryers 
should 
be 
placed 
at 
least 
feet 
(61cm) 
apart 
and 
at 
least 
12” 
(30cm)
   
 from 
washbasin. 
Do 
not 
install 
dryer 
over 
washbasin. 
 Automatic 
dryers 
should
   
 be 
at 
least 
18” 
(46cm) 
above 
any 
projection 
which 
may 
interfere 
with 
the
   
 operation 
of 
the 
automatic 
sensor
.
   
 Hold 
the 
backplate 
to 
the 
wall 
at 
the 
suggested 
mounting 
heig
ht. 
 Measure
   
 from 
bottom 
edge 
of 
backplate
 to 
the 
floor 
(Ref. 
Dimension 
“A” 
Fig. 
1)
DR- 
Hand 
Dryer
 
40” 
(102cm)
 
38”(97cm)
 
28-38”(71-97cm)
 
32” 
 (81cm)
DR-N 
Hand 
Dryer
 
42” 
(107cm)
 
40”(102cm)
 
30-40” 
(76-102cm)
 
34” 
 (86cm)
DR-NH
 Hair 
Dryer
 72” 
(183cm)
 
68”(173cm)
 
46-68”(1
17-173cm)
 
52”(132cm)
4. 
Mark 
the 
locations 
of 
the 
four 
mounting 
holes 
and 
the 
conduit 
entrance
   
 location 
on 
the 
wall. 
(The 
conduit 
entrance 
is 
the 
proper 
hole 
diameter 
for 
1/2
   
 inch 
(13mm) 
conduit.) 
 
5. 
Fasten 
the 
backplate 
to 
the 
wall 
where 
previously 
marked.
   
 RECOMMENDA
TION:
    
W
ood
 wall
 - 
No. 
16 
(M8) 
wood 
screws, 
3/4” 
(70mm) 
long
    
Cement 
or 
brick
 - 
1/4” 
(M6) 
stud 
expansion 
bolts, 
3” 
(76mm) 
long
    
Holl
ow 
wall
 - 
1/4” 
(M6) 
toggle 
bolts, 
length 
depends 
on 
wall 
thickness
6. 
Run 
service 
wire 
to 
the 
dryer 
location 
and 
connect 
to 
the 
terminal 
block.
   
 IMPOR
TANT
: All 
units 
must 
be 
supplied 
with 
wire 
service. 
Use 
No. 
12 
wire
   
 or 
larger
, as 
required 
by 
local 
electrical 
code. 
 The 
ground 
wire 
must 
be
   
 connected 
to 
the 
dryer 
backplate. 
 Unit 
must 
be 
installed 
by 
qualified 
licensed
   
 electrician.
   
 C
ONNEC
tO
 A
 DED
iCA
tED
 C
iRC
uit 
NO
tO
 E
xCEED
 20 
AM
ps.
   
 Dryers 
located
 in 
shower 
rooms 
or 
other 
wet 
locations 
should
 be 
equipped 
   
 with 
ground 
fault 
interrupter(s
).
7. 
 Care
full
y 
replace 
the 
cover 
using 
tamper-proof 
bolt 
supplied. 
Be 
careful 
not 
to 
   
 damage 
circuit 
board 
or 
sensor
. Apply 
bead 
of 
caulk 
around
 edge 
of 
cover 
to 
 
   
 wall.
OWNER’S 
MANUAL
DR
” HAN
AND
 H
Ai
DR
YERS
F
o
r
 I
ns
ta
ll
at
Io
n
 
o
r
 s
er
vI
ce
 
a
ss
Is
ta
nc
e
 P
le
as
e
 c
al
l
(734) 
421-2400 
o
r
Email: 
sales@a
mericandryer
.com
I
m
Po
rt
an
t
:
 
H
av
e
 M
o
de
l
 & 
S
er
ia
l
 N
o
. r
ea
dy
 m
o
de
l
 #______ 
s
er
Ia
l
 #______
MEN
WOMEN
Dis
ABLED
CH
iLDREN
(depends 
on 
age)
iN
st
ALLA
ti
ON 
iN
st
Ru
Cti
ON
s
DISCONNECT 
POWER 
BEFORE 
INST
ALLING
DESUNA 
LA 
ELECTRICIDAD 
ANTES 
DE 
HACER 
REP
ARACIONES
W
ARNING:
AMERICAN 
DR
YER, 
INC.
12932 
FARMINGT
ON 
ROAD, 
LIVONIA, 
MI 
48150, 
U.S.A.
Telephone 
(734) 
421-2400
 •
 Fax 
(734) 
421-5580
www
.americandryer
.com 
• Email: 
sales@americandryer
.com
Rev
. September
 2006