FUNCTION
POSSIBLE CAUSE
REMEDY
4.11  Outer Barrier switch is out of 
adjustment or defective.  
4.12  Full Out switch is not activated or 
defective.  
4.13  Hand-held pendant not working 
properly.
4.00
LIFT WILL 
GO UP WITH 
OVERRIDE 
SWITCH BUT 
NOT WITH 
HAND-HELD 
PENDANT
Check diagnostic LCD for Outer Barrier switch sta-
tus.  Barrier is down or barrier release pin partially 
out.  Adjust or replace switch as necessary.
Check diagnostic LCD for Full Out switch status. 
Adjust or replace switch as necessary.
Check for hand-held pendant illumination and con-
tinuity of the switches.  Verify SW1 and Door Open 
switches are functioning correctly.
5.11  Hydraulic Down valve bad
5.12   Dirty Down valve (clogged)
5.00
LIFT WILL 
NOT GO 
DOWN WITH 
OVERRIDE 
SWITCH 
OR WITH 
HAND-HELD 
PENDANT, 
GOES DOWN 
SLOWLY OR 
LIFT DRIFTS 
DOWN BY 
ITSELF
Check for power on red “valve” wire from P.C. 
board to Down solenoid when pushing override 
switch or hand-held pendant button.  Replace if 
necessary.
Flush valve by operating Up and Down manual 
override switches at same time for 4 to 5 seconds 
several times.
Troubleshooting Diagnosis Chart
6.00
LIFT WILL GO 
DOWN WITH 
OVERRIDE 
SWITCH BUT 
NOT WITH 
HAND-HELD 
PENDANT
6.11  Full Out switch out of adjustment or 
defective.
6.12  SW0 and/or Door Full Close switch-
es out of adjustment or defective.   
Check diagnostic LCD for Full Out switch status.  
Adjust or replace switch as necessary.
Check switches for proper operation/adjustment.  
Adjust or replace switch as necessary.
7.00
LIFT WILL NOT 
EXTEND WITH 
OVERRIDE 
SWITCH OR 
HAND-HELD 
PENDANT
7.11  Poor plug connections
7.12  Bad In/Out motor
7.13  Bad power and ground
Check harness connections A1, A2, B1 and B2
Check power at motor.  Replace motor if necessary.
See 1.00  
8.00
LIFT WILL NOT 
STOW WITH 
HAND-HELD 
PENDANT
8.11  Stow Level switch out of adjust-
ment or defective.  
8.12  Platform is occupied or out of 
calibration
8.13  SW0 and/or Door Full Closed 
switches out of adjustment or 
defective.
8.14  Handrail Belt
Check diagnostic LCD for Stow Level switch sta-
tus.  Adjust or replace switch as necessary.  
Remove weight from platform.  See Platform 
Sense Calibration on page 5.
Check switches for proper operation/adjustment.  
Adjust or replace switch as necessary.
Belt must be latched until platform is at stow level 
and must be unlatched before platform will stow.