Manual Do Utilizadoríndice analíticoCisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide1chapter 13Product Overview1-13chapter 24Preparation for Installation2-14chapter 34Installing the Switches3-14chapter 45Installing Field Replaceable Units4-15chapter 55Managing the Switch5-15chapter 65Hardware Diagnostic Tests6-15appendix A6Specifications and Compliance CertificationsA-16appendix B6Acronyms and Abbreviations36Preface7Audience7Organization7Conventions8Related Documentation14Obtaining Documentation14Cisco.com14Product Documentation DVD15Ordering Documentation15Documentation Feedback15CiscoProduct Security Overview15Reporting Security Problems in CiscoProducts16Product Alerts and Field Notices16Obtaining Technical Assistance17CiscoTechnical Support & Documentation Website17Submitting a Service Request18Definitions of Service Request Severity18Obtaining Additional Publications and Information18Introduction to Switches21Figure1-1 CiscoSFS7000P Server Switch21Figure1-2 CiscoSFS7000D Server Switch22Switch Connectors22Switch Components22LEDs23Power Supply Bay23Power Supply Module23System Features23InfiniBand Connectivity23Scalability24High Availability24Hardware24Ports24Fabric24Figure1-3 Example of Redundant InfiniBand Fabric24Nonblocking Architecture25Administrative Features25Real-Time Clock25Latency25Nonvolatile Memory25Diagnostics25Safety27Site Requirements27Temperature28Humidity28Altitude28Dust and Particles29Corrosion29Electromagnetic and Radio Frequency Interference29Shock and Vibration30Power Source Interruptions30Preventing Electrostatic Discharge Damage30Air Flow31Figure2-1 Air Flow Direction in the CiscoSFS7000P and SFS7000D Server Switches31Power Requirements31Site Preparation Checklist32Table2-1 Site Planning Checklist32Installing the Switches33Safety34Pre-installation Instructions34Rack-Mounting the Switches35Requirements35Rack-Mounting the Switch35Step1 Remove the switch, rack-mount brackets, contents of accessory kit, and documentation from ...35Step2 Place the switch on a secure, clean surface.35Step3 Record the MAC address and the Globally Unique Identifier (GUID) number for future reference.35Step4 Check the slot in the rack for sufficient clearance.36Step5 Determine the desired method of installation, and follow the appropriate steps:36Installing the Switch with One Person36Step1 Separate one set of the rack brackets. (See Figure3-1.)36Figure3-1 Assembled Rack Brackets36Step2 Attach the bracket that has the screw holes to the side of the switch, with the flange fac...36Figure3-2 Attaching One Rail to Switch Chassis36Step3 Repeat Step1 and Step2 on the opposite side of the switch to attach the second bracket.36Step4 Check the rack for clearance for the switch. The switch can be installed either directly o...37Step5 Attach the remaining two rack brackets to your rack.37Figure3-3 Holding Bracket Inside of Rack37Figure3-4 Secure Rail Bracket to Rack with Screws37Step6 Lift the switch unit, and align the sliding brackets to the switch with the brackets attac...37Step7 Carefully push the switch unit into the rack, as shown in Figure3-5.38Figure3-5 Sliding the Switch Into the Rack38Step8 Maintain at least six inches between the cooling vents and any obstructions.38Step9 Secure the switch with your screws through the front of the rack, as shown in Figure3-6.38Figure3-6 Secure Switch with Screws through the Front of the Rack38Installing the Switch with Two People38Step1 Separate the assembled rack brackets. (See Figure3-1.)38Step2 Attach the rack bracket that has screw holes to the sides of the switch by using the screw...39Step3 Attach the rack brackets to their counterparts before inserting the switch into the rack.39Step4 Insert the switch into the rack with the rack bracket attached. You must tilt the switch u...39Step5 Have one person hold the switch while another person secures the switch to the rack.39Step6 Maintain at least six inches between the cooling vents and any obstructions.39Step7 Attach the rack bracket to the back of the rack posts with screws that fit your rack.39Step8 Attach the front rails to the front of the rack with screws that fit your rack. (See Figur...39Configuring Basic Connectivity39Obtaining an IP Address39Obtaining an IP Address from the DHCP Server for Ethernet Management39Obtaining a Static IP Address for Ethernet Management40Figure3-7 Connecting the Console Cable to a Serial Console Port on the Cisco SFS7000P Server Sw...40Figure3-8 Connecting the Console Cable to a Serial Console Port on the Cisco SFS7000D Server Sw...40Step1 Configure the baud rate and character format of the PC terminal emulation program to match...41Step2 Connect the supplied DB-9/RJ-45 female adapter or DB-25/RJ-45 female adapter (depending on...41Step3 Connect one end of the supplied console cable (a flat rollover RJ-45 cable) to the serial ...41Step1 Wait for the login prompt.41Step2 Enter the username and password. The default username is super, and the default password i...41Step3 Enter the enable command.41Step4 Enter the configure command to enter the configuration mode.41Step5 Enter the interface mgmt-ethernet command to enter the config-if-mgmt-ethernet mode.41Step6 Enable the static address option, which turns off the default-enabled DHCP.41Step7 Enter the IP address of the management interface, followed by the netmask, which enables t...41Step8 Set the default gateway for the management interface. See your system administrator for a ...42Step9 Enable the management interface by entering the no shutdown command.42Step10 Save the configuration to preserve it between reboots.42Connecting the 10/100 Ethernet Management Port42Powering Up the Chassis42Step1 Remove the power cords from the shipping package.42Step2 Inspect the power cord to determine if it provides the proper plug and is appropriately ce...42Step3 Connect the power cords to the power connectors on the rear of the switch.42Figure3-9 Power Connector Locations for the Cisco SFS7000P Server Switch43Figure3-10 Power Connector Locations for the Cisco SFS7000D Server Switch43Step4 Connect the other end of each AC power cable into a 90-to 264-VAC power outlet operating b...43Step5 Check the LEDs on the front of the Server Switch.43Step6 Log in and assign a network address after you see the login prompt.43Connecting Network Devices43Connecting InfiniBand Devices44Figure3-11 Port Connections for the Cisco SFS7000P Server Switch44Figure3-12 Port Connections for the Cisco SFS7000D Server Switch44Step1 Connect InfiniBand cables from the host to the InfiniBand switch.45Figure3-13 InfiniBand Cable with Pinch Connector45Figure3-14 InfiniBand Cable with Pull Connector45Figure3-15 Removing a Pinch Connector46Figure3-16 Removing a Pull Connector46Connecting Ethernet Management Devices46Managing the System46Power Supply Modules49Locating the Power Supply Unit49Failed Power Supply Modules49Installing a Power Supply Module50Step1 Ground yourself appropriately.50Step2 Remove the filler panel from the power supply bay with a number 1 Phillips or a slotted sc...50Figure4-1 Removing a Filler Panel from the Switch50Step3 Remove the power supply module if one is in place by pulling on the black handle. (See Fig...51Figure4-2 Removing the Power Supply from the Switch51Step4 Insert the new power supply module into the open slot until it is fully seated. You might ...51Step5 Secure fasteners with a number 1 Phillips or a slotted screwdriver.51Step6 Check the LEDs to verify the status of the module. (See Figure4-3 for the location of the...51Figure4-3 Power Supply LEDs51Removing Power Supply Modules52Step1 Make sure you have a number 1 Phillips or a slotted screwdriver to disengage the fasteners.52Step2 Ground yourself appropriately.52Step3 Locate the power supply module that you want to remove.52Step4 Unscrew the fasteners that hold the power supply module in place. (See Figure4-4.)52Figure4-4 Removing the Screws from the Power Supply of the Switch52Step5 Pull the unit from the bay.52Step6 Install the filler panel in place of the power supply module, or install a new power suppl...52LEDs53Chassis Status LEDs53Table5-1 Interpreting the Chassis Status LED53Figure5-1 Front View of CiscoSFS7000P Server Switch Showing Chassis Status LED54Figure5-2 Front View of Cisco SFS7000D Server Switch Showing Chassis Status LED54Figure5-3 Rear View of CiscoSFS7000P Server Switch Showing Chassis Status LEDs54Figure5-4 Rear View of Cisco SFS7000D Server Switch Showing Chassis Status LEDs54InfiniBand Port LEDs55Figure5-5 InfiniBand Port LEDs Location for the CiscoSFS7000P Server Switch55Figure5-6 InfiniBand Port LEDs Location for the Cisco SFS7000D Server Switch55Table5-2 InfiniBand Port LED55Power Supply LEDs55Figure5-7 Power Supply and Fan LEDs Location56Table5-3 Power Supply Module LEDs56Managing the System with Element Manager56Step1 Launch the Element Manager.56Step2 Select Health > Status. The Health Status window opens. (See Figure5-8.)56Figure5-8 Health Status Window56Using the Summary Tab57Using the Power Supplies Tab57Figure5-9 Health Status Power Supplies Window57Using the Fans Tab57Figure5-10 Health Status Fans Window57Using the Sensors Tab58Figure5-11 Health Status Sensors Window58Displaying System Information58Displaying Power Supply Information58Displaying Fan Information59Displaying Sensor Information59About Diagnostic Tests61LED Tests61Self-Tests61Running Card Self-Test62Step1 Enter the diag card number command.62Step2 Exit the test to view the progress of the test.62Step3 Enter the show diagnostic card # command.62Step4 If the test fails, enter the more syslog:hwif_log command to see the log information.62Running Chassis Self-Test63Step1 Start the test by entering the diag chassis test standard command and the start command.63Step2 Display the status of the test by entering the show diag chassis command.63Step3 Display any errors on individual components by entering the show diag post command.64Running Fan Self-Test64Step1 Identify the number of the fan you want to diagnose, if you do not already know the number...64Figure6-1 Power Supply Numbers on the Cisco SFS7000P and SFS7000D Server Switches65Step2 Enter the diag fan id command.65Step3 Display the progress of the test by entering the show diag fan command.65Step4 Display any errors that appear in the result string by entering the show diag fru-error co...66Step5 Reboot the chassis when the self-test is complete.66Running Power Supply Tests66Running a LED Test on the Power Supply67Running a Self-Test on a Power Supply67Step1 Determine the ID of the power supply that you want to diagnose, if you do not already know...67Step2 Specify the type of test (self-test is chosen by default) by entering the diag power-suppl...67Step3 Start the test.67Step4 Display the progress of the test by entering the show diag fan command.67Step5 Display any errors that appear in the result string by entering the show diag fru-error co...67Step6 Reboot the chassis when the self-test is complete.68Displaying Hardware Errors68Step1 Enter the more syslog:hwif_log command to see the contents of the hardware log file.68Step2 Display FRU errors on your switch by entering the show diagnostic fru-error command.69Table6-1 Cisco SFS7000P and SFS7000D Server Switches Power Supply Errors69A71Specifications and Compliance Certifications71Chassis and Management Interface71TableA-1 CiscoSFS7000P and SFS7000D Server Switches and Management General Specifications71Electrical Specifications72TableA-2 CiscoSFS7000P and SFS7000D Server Switches Electrical Specifications72B73Acronyms and Abbreviations73TableB-1 List of Acronyms and Abbreviations73A75B75C75D75E76F76G76H76I77L77M77N77O78P78R78S78T79U79V79W79Tamanho: 6 MBPáginas: 80Language: EnglishAbrir o manual