Manual Do Utilizadoríndice analíticoInvacare® Select1Compressor Nebulizer System1Model IRC 17051m warning2DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as owner’s manuals, service manuals or instruction sheets supplied with...2Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories. Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invacare products.2Register Your Product 43special notes 53important safeguards 63introduction 113typical product parameters 123supplemental information 143Compressor 143Extension Cords 143section 1—handling 153Shipping Instructions 153Unpacking 153Inspection 153section 2—operating instructions 163Setup 163Treatment Instructions 193section 3—Cleaning and Disinfecting 203Cleaning the Outer Case 203Cleaning the Nebulizer 213Cleaning the Compressor 233Cleaning the Mouthpiece 234section 4—mAINTENANCE 244Routine Care 244Storage 244Nebulizer Change 254Filter Change 254section 5—TROUBLESHOOTING 264Limited Warranty 294Register Your Product4The benefits of registering include:41. Safeguarding your investment.42. Ensuring long-term maintenance and servicing of your product.43. Receiving updates with product information, maintenance tips and industry news.4Register online at warranty.invacare.com4Please have your model number and purchase date available to complete your registration.4Any registration information you submit will only be used by Invacare Corporation and protected as required by applicable laws and regulations.4special notes5Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. Refer to the table below for definitions of the signal words.5Signal Word5meaning5NOTICE5The information contained in this document is subject to change without notice.5important safeguards6m warning6IMPORTANT SAFEGUARDS contains important information for the safe operation and use of this product.6caution6Federal law restricts this device to sale or rental by or on the order of a physician, or any other practitioner licensed by the law of the State in which he/she practices to use or order the use of this device.6“This appliance has a polarized plug (one blade is wider than the other). As a safety feature, this plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact ...6m warning6When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following:6READ ALL INSTRUCTIONS BEFORE USING7c danger7FIRE RISK - DO NOT use this product in an oxygen enriched environment (i.e – oxygen tent).7Risk of electric shock. DO NOT disassemble. Refer servicing to qualified service personnel.7To Reduce the Risk of Electrocution:7ALWAYS unplug this product IMMEDIATELY after using.7DO NOT use while bathing.7DO NOT place or store product where it can fall or be pulled into a tub or sink.7DO NOT place in or drop into water or other liquid.7DO NOT reach for a product that has fallen into water. Unplug IMMEDIATELY.7m warning8To Reduce the Risk of Burns, Electrocution, Fire and Injury to Persons:8This product should NEVER be left unattended when plugged in.8Close supervision is necessary when this product is used by, on, or near children and physically challenged individuals.8Use this product only for its intended use as described in this manual and only with the prescribed medication. Use this product only under physician’s direction.8NEVER operate this product with a damaged cord or plug, if it is not working properly, if it was dropped or damaged, or if it was dropped into water. Call qualified service personnel for examination and repair.8m warning9Keep the nebulizer tubing, cord, and unit away from heated or hot surfaces, including space heaters, electric blankets, stoves and similar electrical appliances.9NEVER drop or insert objects into any opening or hose.9NEVER use while sleeping or drowsy.9NEVER block the air openings of the product or place it on a soft surface, such as a bed or couch, where the air openings may be blocked. Keep the air openings free from lint, hair and the like. Blocked openings may cause the unit to shut down. Conta...9The compressor nebulizer system uses the surrounding air to effectively administer the prescribed medication through the nebulizer. The user and administrator should be aware of surroundings so as not to have contaminated air filtered through the com...9DO NOT use the compressor nebulizer system in these environments. Otherwise, serious bodily injury may occur.9This unit is oil-less. DO NOT lubricate.9m warning10This equipment is not suitable for use in the presence of a flammable anesthetic mixture with air or with nitrous oxide.10When not administering treatment, keep out of the reach of small children. Some of the parts of the nebulizer are small enough for children to swallow. The tubing may present a strangulation hazard10NEVER touch the unit with wet hands.10DO NOT pull on the power cord to unplug the unit from an electrical outlet.10DO NOT overload wall outlets.10Maintenance MUST be performed by a qualified service technician.10save these instructions10introduction11The Invacare Select Compressor Nebulizer System is a portable medical device designed to efficiently deliver physician-prescribed medication to the bronchial lung passages. The nebulizer system consists of the following components:11• Compressor11• Nebulizer11• Air tubing11• Mouthpiece11typical product parameters12NOTE: Product parameters and appearance are subject to change without notice for purposes of improvement.13NOTE: Nebulization rate and particle size are dependent on the characteristics of the nebulizer chosen.13supplemental information14Compressor14If the unit shuts down frequently, you may have a low voltage situation.14Low voltage can also be suspected when:14• The motor does not get up to full power or speed.14• Home fuses or circuit breakers activate when starting compressor.14• Lights dim or remain dim when compressor is started.14• Other motor operated appliances fail to operate properly or too many motor operated appliances are on same circuit.14Extension Cords14If you must use an extension cord, use only a cord having the same or higher electrical rating as the device being connected. Make certain the extension cord is in good condition without any exposed wires or hazardous contacts, and the extension cord...14Section 1— handling15Shipping Instructions15The shipping container has been designed to assure protection of this device.15If this device is to be reshipped by common carrier, it should be packed in the same carton.15Unpacking151. Check for any obvious damage to the carton or its contents. If damage is evident, DO NOT use. Notify carrier/Invacare or your local Invacare dealer.152. Remove all the loose packing from the carton.153. Carefully remove all the components from the carton.15NOTE: Retain carton and packing materials for use in shipping or storing the unit until use is required.15Inspection151. Examine exterior for damage. Inspect all components.15Section 2— operating instructions16m warning16DO NOT operate unit without filter.16Avoid operating this product in a dusty environment. Otherwise, premature compressor wear could occur.16NOTE: Clean and disinfect the nebulizer and mouthpiece before using the device for the first time. Refer to Cleaning and Disinfecting on page 20.16Setup16NOTE: For this procedure, refer to FIGURE 2.1 on page 17.161. Place the unit on a table or other flat, stable surface. Be sure you can easily reach the controls when you are seated.16caution16Make sure the power switch is in the off “O” position.162. Gently twist the nebulizer to separate it into two sections.163. Be sure the pick-up funnel is in place in the bottom section of the nebulizer.17Caution17DO NOT add over 6 ml of medication to the medication cup.The maximum capacity of the nebulizer medication cup is 6 ml.174. Add the prescribed amount of medication to the cup of the nebulizer using an eyedropper, pre-measured dose or ampoule.17Eyedropper17FIGURE 2.1 Adding Medication175. Gently twist the top and bottom sections together to assemble the nebulizer. Be sure the two sections fit securely.176. Attach one end of the air tubing to the air tubing connector located on the front of the compressor.177. Attach the other end of the air tubing to the base of the nebulizer.18NOTE: Ensure nebulizer tubing is firmly attached to compressor before use.18m warning18In the case of high humidity, condensation may form inside the internal tubing. Run the unit for two minutes before connecting the nebulizer to the tubing.188. Attach the mouthpiece to the top section of the nebulizer. Refer to the nebulizer manual for additional instructions.18NOTE: Before starting a cold unit, let the unit reach room temperature in a heated area.189. With the power switch off, plug the power cord into an appropriate electrical outlet.18caution18This device is for intermittent use: 30 min. ON / 30 min. OFF. Failure to operate within these limits could damage the device beyond repair.18Treatment Instructions19NOTE: For this procedure, refer to FIGURE 2.2.191. Turn the unit on, pressing the ON/OFF switch to the “I” position.192. Place mouthpiece between your teeth, close your mouth and tilt the nebulizer toward your mouth.19FIGURE 2.2 Using the Nebulizer193. As aerosol begins to flow, inhale deeply, slowly, and hold breath for ten seconds. Then exhale slowly through the mouthpiece.19NOTE: If you need to rest during a treatment, be sure the nebulizer remains in an upright position; otherwise, the medication may spill.194. When treatment is complete, turn the unit off by setting the switch to the “O” position and unplug the unit from the electrical outlet.195. Before storing supplies between treatments, clean and dry the nebulizer and accessories. Refer to Cleaning and Disinfecting on page 20.19Section 3— Cleaning and Disinfecting20Following the cleaning instructions after each use will prevent any remaining medication in the nebulizer cup from drying and causing the device to nebulize ineffectively.20It is recommended that the nebulizer and the mouthpiece be thoroughly rinsed with hot tap water after each use and cleaned with a mild detergent after the last treatment of the day. The same pieces MUST also be disinfected daily by soaking in a vineg...20Cleaning the Outer Case20m warning20Unplug unit before cleaning.20DO NOT submerge in water to clean. Clean outer case with damp cloth.20c danger21DO NOT attempt to separate the outer case of this unit. Removing the case creates a serious electrical shock hazard. All disassembly and maintenance of this unit MUST be done by a qualified technician.21Cleaning the Nebulizer21m warning21To prevent possible risk of infection due to contamination, follow these instructions:21• Clean the nebulizer before initial operations.21• Clean the nebulizer after each aerosol treatment.21• ALWAYS use fresh cleaning solution.21• DO NOT towel dry the nebulizer components after cleaning.21NOTE: Your physician and/or an Invacare dealer may specify certain cleaning procedures. If so, follow their recommendations. If not, clean according to the following instructions:211. Remove the nebulizer and mouthpiece from the tubing.212. Disassemble nebulizer chamber by turning counterclockwise and separating.223. Fill two plastic containers or bowls:22a. Washing: Hot water/detergent solution.22b. Soaking: Hot water/vinegar solution (one part vinegar to three parts water).224. Thoroughly clean the nebulizer and mouthpiece in hot water/detergent solution.225. Remove from the water/detergent solution and rinse with clear hot tap water.226. Soak in hot water/vinegar solution for 30 minutes.227. Rinse with hot tap water again and air dry thoroughly.22NOTE: If using medical disinfectant cleaners, follow manufacturer’s instructions carefully.228. Keep the outer surface of the tubing dust-free by wiping regularly.22NOTE: The nebulizer air tubing does not have to be washed internally because only filtered air passes through the tubing.22Cleaning the Compressor23CAUTION23Unplug unit before cleaning. DO NOT submerge in water to clean.23DO NOT clean using abrasive cleaners.231. Clean the casing of the main unit daily by using a soft cloth moistened with water or a mild detergent.232. Wipe the casing and immediately dry using a soft clean cloth.23Cleaning the Mouthpiece231. Boil the mouthpiece in water for a maximum of five minutes or autoclave at a maximum of 121° C for ten minutes.232. Allow the mouthpiece to air dry.233. Once dry, the mouthpiece may be stored inside the nebulizer top.23Section 4— mAINTENANCE24c danger24DO NOT attempt to separate the outer case of this unit. Removing the case creates a serious electrical shock hazard. All disassembly and maintenance of this unit MUST be done by a qualified technician.24Routine Care24To keep your device in the best condition and protect the unit from damage, follow these directions:24• DO NOT subject the device or the parts to any strong shocks such as dropping the device on the floor.24• DO NOT store the device in extreme hot or cold temperatures, high humidity or under direct sunlight.24Storage24Store the repackaged device in a dry and safe area. DO NOT place other objects on top of the repackaged device.24Nebulizer Change25The nebulizer is designed for single patient use. The nebulizer MUST be replaced after a long period of inactivity, or when it is obstructed by dry medication, dust, etc. Reusable nebulizers should last from six months to one year with general use. R...25Filter Change251. The filter MUST be replaced after approximately 30 hours of use or when it turns grey.252. Open the filter holder to replace the filter with a new one.25caution25DO NOT use cotton or any other material.25DO NOT wash or clean the filter.25Use only Invacare filters.25DO NOT operate unit without an air filter.25Section 5— TROUBLESHOOTING26Problem26Solution26Notes27Notes28Limited Warranty29PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975.29This warranty is extended only to the original purchaser who purchases this product when new and unused from Invacare Corporation or a dealer. This warranty is not extended to any other person or entity and is not transferable or assignable to any su...29Invacare warrants this product when purchased new and unused to be free from defects in materials and workmanship for a period of 3 years from date of purchase from Invacare or a dealer, with a copy of the seller’s invoice required for coverage und...29For warranty service, please contact the Invacare service department during normal business hours at the toll-free telephone number identified on the back cover of this manual. Upon receiving notice of an alleged defect in a product, Invacare will is...29LIMITATIONS AND EXCLUSIONS: THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BEEN REMOVED OR DEFACED; PRODUCTS SUBJECTED TO NEGLIGENCE, ACCIDENT, IMPROPER OPERATION, MAINTENANCE, OR STORAGE; PRODUCTS MODIFIE...30THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES WHATSOEVER, WHETHER EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND THE SOLE REMEDY FOR VIOLATIONS OF ...31Some states do not allow the exclusion or limitation of incidental or consequential damage, or limitation of how long an implied warranty lasts, so the above exclusion and limitation may not be applicable.31THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE/PROVINCIAL LAWS AND REQUIREMENTS.31Part No 114807332Rev B - 12/0832Tamanho: 400 KBPáginas: 32Language: EnglishAbrir o manual